Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
753
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0460 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,871 | $80,231 | Not Implemented |
NC0460 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,787 | $6,902 | Not Implemented |
NC0460 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $42,119 | $4,405 | Not Implemented |
NC0460 # 08 Y:2012 | 08 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,624 | $0 | Not Implemented |
NC0460 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,756 | $500 | Implemented |
NC0460 # 10 Y:2012 | 10 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,532 | $3,200 | Not Implemented |
NC0460 # 11 Y:2012 | 11 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $6,426 | $7,515 | Not Implemented |
NC0460 # 12 Y:2012 | 12 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $897 | $1,290 | Not Implemented |
NC0460 # 13 Y:2012 | 13 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $119 | $11 | Not Implemented |
NC0440 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $157,713 | $165,618 | Implemented |
NC0440 # 02 Y:2011 | 02 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $15,127 | $20,158 | Implemented |
NC0440 # 03 Y:2011 | 03 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,350 | $800 | Not Implemented |
NC0440 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,025 | $500 | Implemented |
NC0440 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,312 | $8,420 | Implemented |
NC0424 # 01 Y:2011 | 01 | 2011 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $51,507 | $142,273 | Not Implemented |
NC0424 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,681 | $112,768 | Implemented |
NC0424 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,430 | $4,435 | Implemented |
NC0424 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,685 | $78,795 | Implemented |
NC0424 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,791 | $100 | Implemented |
NC0424 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,638 | $74,990 | Not Implemented |
NC0407 # 01 Y:2010 | 01 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,128 | $60,000 | Implemented |
NC0407 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $35,567 | $200,000 | Not Implemented |
NC0407 # 03 Y:2010 | 03 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,606 | $1,000 | Implemented |
NC0407 # 04 Y:2010 | 04 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,147 | $42,000 | Implemented |
NC0407 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $350 | $50 | Not Implemented |