Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

67

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0334 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,339 $391 Implemented
MS0334 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,097 $53,432 Not Implemented
MS0334 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $17,689 $11,700 Not Implemented
MS0334 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $43,579 $39,390 Not Implemented
MS0334 # 05 Y:2008 05 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,805 $2,170 Not Implemented
MS0310 # 04 Y:2007 04 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $105 $82 Implemented
MS0310 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,338 $6,046 Implemented
MS0310 # 01 Y:2007 01 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,634 $7,425 Implemented
MS0310 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $755 $144 Implemented
MS0295 # 03 Y:2006 03 2006 REPAIR AND ELIMINATE STEAM LEAKS $6,813 $37 Implemented
MS0295 # 04 Y:2006 04 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,542 $3,825 Implemented
MS0295 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,061 $87,943 Implemented
MS0295 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,158 $36,274 Implemented
MS0295 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $395 $48 Implemented
MS0295 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,141 $223 Implemented
MS0295 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,014 $410 Not Implemented
MS0217 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $5,071 $799 Not Implemented
MS0217 # 03 Y:2002 03 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,081 $35,838 Not Implemented
MS0217 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,022 $38,355 Not Implemented
MS0217 # 01 Y:2002 01 2002 INSTALL HEAT PIPES / RAISE COOLING SETPOINT $236,267 $271,000 Not Implemented
MS0217 # 06 Y:2002 06 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,555 $3,249 Not Implemented
MS0217 # 07 Y:2002 07 2002 INSULATE BARE EQUIPMENT $1,276 $1,003 Not Implemented
MS0217 # 08 Y:2002 08 2002 INSULATE BARE EQUIPMENT $529 $354 Not Implemented
MS0217 # 09 Y:2002 09 2002 DISCONNECT BALLASTS $431 $510 Not Implemented
MS0217 # 10 Y:2002 10 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $249 $155 Not Implemented