matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0440 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,025 | $500 | Implemented |
NC0440 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,312 | $8,420 | Implemented |
NC0440 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $157,713 | $165,618 | Implemented |
NC0440 # 03 Y:2011 | 03 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,350 | $800 | Not Implemented |
NC0440 # 02 Y:2011 | 02 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $15,127 | $20,158 | Implemented |
TT0078 # 02 Y:2011 | 02 | 2011 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $10,364 | $5,531 | Not Implemented |
TT0078 # 01 Y:2011 | 01 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,585 | $29,500 | Not Implemented |
TT0078 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,720 | $800 | Implemented |
TT0078 # 03 Y:2011 | 03 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,023 | $1,480 | Implemented |
TT0078 # 05 Y:2011 | 05 | 2011 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $15,241 | $12,500 | Not Implemented |
UA0066 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $22,864 | $30,000 | Implemented |
UA0066 # 09 Y:2011 | 09 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,013 | $1,266 | Not Implemented |
UA0066 # 08 Y:2011 | 08 | 2011 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $26,728 | $64,000 | Not Implemented |
UA0066 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,677 | $640 | Implemented |
UA0066 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $22,848 | $11,400 | Implemented |
UA0066 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $100,439 | $14,349 | Not Implemented |
UA0066 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $98,887 | $13,568 | Implemented |
UA0066 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,215 | $62,771 | Implemented |
UA0066 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,963 | $3,900 | Implemented |
UA0066 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $2,224 | $4,767 | Not Implemented |
GT0883 # 06 Y:2011 | 06 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $42,689 | $368,265 | n/a |
GT0883 # 05 Y:2011 | 05 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,404 | $46,133 | n/a |
GT0883 # 04 Y:2011 | 04 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $34,385 | $107,085 | n/a |
GT0883 # 03 Y:2011 | 03 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,504 | $36,650 | n/a |
GT0883 # 02 Y:2011 | 02 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,435 | $800 | n/a |