Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
151
matching recommendationsSIC | 2211 | Broadwoven Fabric Mills, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0310 # 01 Y:2007 | 01 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,634 | $7,425 | Implemented |
GT0819 # 04 Y:2006 | 04 | 2006 | DISCONNECT BALLASTS | $2,735 | $3,678 | Implemented |
GT0819 # 01 Y:2006 | 01 | 2006 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $140,000 | $10,000 | Implemented |
GT0819 # 02 Y:2006 | 02 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,030 | $4,800 | Implemented |
GT0819 # 03 Y:2006 | 03 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $18,798 | $5,000 | Implemented |
GT0819 # 05 Y:2006 | 05 | 2006 | USE EXISTING DAM TO GENERATE ELECTRICITY | $106,850 | $94,000 | Implemented |
NC0284 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,310 | $26,200 | Implemented |
NC0284 # 02 Y:2004 | 02 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,667 | $10,600 | Implemented |
NC0284 # 07 Y:2004 | 07 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $469 | $1,000 | Implemented |
NC0284 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,521 | $1,002 | Implemented |
GT0767 # 01 Y:2003 | 01 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,362 | $100 | Implemented |
GT0767 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $15,699 | $2,088 | Implemented |
GT0767 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,500 | $1,250 | Implemented |
GT0766 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,589 | $49,906 | Implemented |
GT0766 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,159 | $6,250 | Implemented |
GT0766 # 05 Y:2003 | 05 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $5,000 | $1,000 | Implemented |
GT0766 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $32,869 | $500 | Implemented |
AM0434 # 06 Y:2003 | 06 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,510 | $0 | Implemented |
AM0434 # 04 Y:2003 | 04 | 2003 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $7,300 | $89,640 | Implemented |
LM0058 # 01 Y:2003 | 01 | 2003 | ADD AREA LIGHTING SWITCHES | $6,786 | $7,274 | Implemented |
AM0434 # 03 Y:2003 | 03 | 2003 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $8,000 | $800 | Implemented |
AM0434 # 07 Y:2003 | 07 | 2003 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $3,500 | $0 | Implemented |
AM0434 # 08 Y:2003 | 08 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,300 | $0 | Implemented |
AM0434 # 10 Y:2003 | 10 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $965 | $800 | Implemented |
LM0058 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,174 | $250 | Implemented |