Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
263
matching recommendationsSIC | 222 | Broadwoven Fabric Mills, Manmade |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0102 # 03 Y:1998 | 03 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,038 | $1,930 | Implemented |
MS0102 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,041 | $0 | Implemented |
MS0102 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $22,934 | $8,025 | Not Implemented |
OD0092 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,107 | $1,495 | Implemented |
OD0092 # 07 Y:1997 | 07 | 1997 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $44,642 | $16,696 | Not Implemented |
OD0092 # 06 Y:1997 | 06 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,500 | $4,095 | Implemented |
OD0092 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,299 | $9,865 | Implemented |
OD0092 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $562 | $2,705 | Implemented |
OD0092 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $32,105 | $53,256 | Implemented |
OD0092 # 03 Y:1997 | 03 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,578 | $6,300 | Implemented |
ME0208 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $738 | $200 | Not Implemented |
ME0208 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM THICKNESS INSULATION | $788 | $290 | Implemented |
ME0208 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,030 | $600 | Implemented |
ME0208 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,766 | $20 | Implemented |
ME0208 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,949 | $3,274 | Not Implemented |
ME0208 # 10 Y:1997 | 10 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $143 | $400 | Implemented |
ME0208 # 09 Y:1997 | 09 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $24,276 | $6,900 | Implemented |
ME0208 # 08 Y:1997 | 08 | 1997 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $354 | $0 | Not Implemented |
ME0208 # 07 Y:1997 | 07 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $452 | $0 | Implemented |
ME0208 # 04 Y:1997 | 04 | 1997 | PAY UTILITY BILLS ON TIME | $1,220 | $0 | Implemented |
TN0598 # 01 Y:1997 | 01 | 1997 | REDUCE SCRAP PRODUCTION | $151,000 | $13,920 | n/a |
TN0598 # 09 Y:1997 | 09 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,196 | $4,750 | n/a |
TN0598 # 02 Y:1997 | 02 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $95,500 | $12,800 | n/a |
TN0598 # 03 Y:1997 | 03 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $59,900 | $10,000 | n/a |
TN0598 # 06 Y:1997 | 06 | 1997 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,685 | $13,600 | n/a |