Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

103

matching recommendations
Reset
SIC 223 Broadwoven Fabric Mills, Wool
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0111 # 03 Y:1991 03 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $877 $500 Implemented
OR0111 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $1,153 $0 Implemented
OR0111 # 05 Y:1991 05 1991 DIRECT WARMEST AIR TO COMBUSTION INTAKE $240 $470 Implemented
OR0111 # 06 Y:1991 06 1991 OPTIMIZE PLANT POWER FACTOR $638 $1,350 Implemented
OR0111 # 07 Y:1991 07 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $272 $671 Implemented
OR0111 # 08 Y:1991 08 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $58 $240 Implemented
OR0111 # 09 Y:1991 09 1991 MODIFY DYE BECK $1,526 $6,422 Implemented
MA0187 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,894 $7,048 Implemented
GT0405 # 01 Y:1990 01 1990 DISCONNECT BALLASTS $500 $950 Implemented
GT0405 # 03 Y:1990 03 1990 INSTALL SET-BACK TIMERS $570 $400 Implemented
GT0405 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $27,873 $4,000 Implemented
GT0405 # 06 Y:1990 06 1990 INCREASE AMOUNT OF CONDENSATE RETURNED $36,022 $10,000 Implemented
GT0400 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,030 $8,080 Implemented
GT0400 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,063 $2,752 Implemented
GT0400 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,520 $0 Implemented
GT0400 # 05 Y:1990 05 1990 MODIFY TEXTILE DRYERS $66,450 $0 Implemented
OR0067 # 02 Y:1989 02 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $2,279 $385 Implemented
OR0067 # 04 Y:1989 04 1989 INCREASE AMOUNT OF CONDENSATE RETURNED $4,079 $4,000 Implemented
OR0067 # 05 Y:1989 05 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,207 $1,800 Implemented
OR0067 # 06 Y:1989 06 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,243 $1,755 Implemented
MA0032 # 06 Y:1985 06 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,902 $2,400 Implemented
MA0032 # 07 Y:1985 07 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $485 $120 Implemented
GT0215 # 01 Y:1984 01 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $11,255 $24,000 Implemented
GT0215 # 02 Y:1984 02 1984 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $852 $3,000 Implemented
GT0215 # 03 Y:1984 03 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $1,517 $572 Implemented