Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
181
matching recommendationsSIC | 223 | Broadwoven Fabric Mills, Wool |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0825 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $13,107 | $1,500 | Not Implemented |
GT0825 # 02 Y:2006 | 02 | 2006 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $95,828 | $140,000 | Not Implemented |
GT0825 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $78,754 | $182,180 | Not Implemented |
GT0825 # 01 Y:2006 | 01 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,828 | $0 | Not Implemented |
GT0825 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,150 | $4,150 | Not Implemented |
OR0487 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,500 | $600 | Not Implemented |
OR0487 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,600 | $23,000 | Not Implemented |
OR0487 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,100 | $104 | Implemented |
OR0487 # 01 Y:2005 | 01 | 2005 | MINIMIZE WATER USAGE | $215,000 | $620,000 | Not Implemented |
OR0487 # 06 Y:2005 | 06 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,637 | $3,150 | Implemented |
OR0487 # 03 Y:2005 | 03 | 2005 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $39,000 | $16,400 | Not Implemented |
OR0487 # 02 Y:2005 | 02 | 2005 | MINIMIZE WATER USAGE | $51,000 | $107,000 | Not Implemented |
OR0487 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,630 | $0 | Implemented |
SF0246 # 06 Y:2002 | 06 | 2002 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $67,254 | $7,095 | Not Implemented |
SF0246 # 05 Y:2002 | 05 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $16,661 | $16,445 | Not Implemented |
SF0246 # 03 Y:2002 | 03 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $8,497 | $22,500 | Not Implemented |
SF0246 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $285 | $166 | Implemented |
SF0246 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $853 | $3,180 | Implemented |
SF0246 # 01 Y:2002 | 01 | 2002 | USE PHOTOCELL CONTROLS | $800 | $240 | Not Implemented |
UF0284 # 04 Y:2001 | 04 | 2001 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $6,860 | $1,212 | Not Implemented |
UF0284 # 10 Y:2001 | 10 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $7,350 | $800 | Implemented |
UF0284 # 02 Y:2001 | 02 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $17,357 | $50 | Not Implemented |
UF0284 # 09 Y:2001 | 09 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $29,484 | $5,113 | Not Implemented |
UF0284 # 08 Y:2001 | 08 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,485 | $0 | Implemented |
UF0284 # 03 Y:2001 | 03 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $20,280 | $49,350 | Not Implemented |