Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
532
matching recommendationsSIC | 225 | Knitting Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0272 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $569 | $151 | Implemented |
MS0272 # 05 Y:2005 | 05 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $424 | $1,495 | Not Implemented |
MS0272 # 06 Y:2005 | 06 | 2005 | DISCONNECT BALLASTS | $153 | $216 | Implemented |
MS0272 # 07 Y:2005 | 07 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $95 | $19 | Implemented |
NC0300 # 01 Y:2004 | 01 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,985 | $1,000 | Not Implemented |
NC0300 # 02 Y:2004 | 02 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,558 | $5,000 | Implemented |
NC0300 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,308 | $100 | Implemented |
NC0300 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,688 | $6,890 | Not Implemented |
NC0300 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $1,402 | $4,751 | Implemented |
GT0792 # 08 Y:2004 | 08 | 2004 | CONTROL PRESSURE ON STEAMER OPERATIONS | $39,600 | $32,100 | Not Implemented |
GT0792 # 07 Y:2004 | 07 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,310 | $8,000 | Not Implemented |
GT0792 # 06 Y:2004 | 06 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $41,148 | $96,250 | Not Implemented |
GT0792 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,100 | $75,700 | Not Implemented |
GT0792 # 04 Y:2004 | 04 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $9,228 | $11,000 | Implemented |
GT0792 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,050 | $616 | Implemented |
GT0792 # 02 Y:2004 | 02 | 2004 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $19,495 | $3,060 | Implemented |
GT0792 # 01 Y:2004 | 01 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $21,335 | $10,000 | Implemented |
NC0294 # 05 Y:2004 | 05 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,102 | $9,225 | Implemented |
NC0294 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $600 | $100 | Implemented |
NC0294 # 03 Y:2004 | 03 | 2004 | REDESIGN PROCESS | $9,178 | $2,200 | Not Implemented |
NC0294 # 02 Y:2004 | 02 | 2004 | ADD ADDITIONAL PRODUCTION SHIFT | $17,395 | $5,000 | Not Implemented |
NC0294 # 01 Y:2004 | 01 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $19,084 | $2,780 | Implemented |
NC0298 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $219 | $100 | Implemented |
NC0298 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $797 | $1,315 | Not Implemented |
NC0298 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,037 | $1,335 | Implemented |