Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

40

matching recommendations
Reset
SIC 225 Knitting Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0300 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,688 $6,890 Not Implemented
NC0300 # 02 Y:2004 02 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,558 $5,000 Implemented
NC0300 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $9,308 $100 Implemented
NC0300 # 01 Y:2004 01 2004 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $1,985 $1,000 Not Implemented
NC0300 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $1,402 $4,751 Implemented
GT0792 # 07 Y:2004 07 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $5,310 $8,000 Not Implemented
GT0792 # 06 Y:2004 06 2004 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $41,148 $96,250 Not Implemented
GT0792 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,100 $75,700 Not Implemented
GT0792 # 04 Y:2004 04 2004 REPAIR OR REPLACE STEAM TRAPS $9,228 $11,000 Implemented
GT0792 # 08 Y:2004 08 2004 CONTROL PRESSURE ON STEAMER OPERATIONS $39,600 $32,100 Not Implemented
GT0792 # 03 Y:2004 03 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,050 $616 Implemented
GT0792 # 02 Y:2004 02 2004 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $19,495 $3,060 Implemented
GT0792 # 01 Y:2004 01 2004 REPAIR AND ELIMINATE STEAM LEAKS $21,335 $10,000 Implemented
NC0294 # 02 Y:2004 02 2004 ADD ADDITIONAL PRODUCTION SHIFT $17,395 $5,000 Not Implemented
NC0294 # 05 Y:2004 05 2004 RECOVER WASTE HEAT FROM EQUIPMENT $8,102 $9,225 Implemented
NC0294 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $600 $100 Implemented
NC0294 # 03 Y:2004 03 2004 REDESIGN PROCESS $9,178 $2,200 Not Implemented
NC0294 # 01 Y:2004 01 2004 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $19,084 $2,780 Implemented
NC0298 # 05 Y:2004 05 2004 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $21,805 $15,800 Not Implemented
NC0298 # 06 Y:2004 06 2004 INCREASE AMOUNT OF CONDENSATE RETURNED $1,388 $900 Implemented
NC0298 # 04 Y:2004 04 2004 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $1,175 $1,200 Implemented
NC0298 # 08 Y:2004 08 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $797 $1,315 Not Implemented
NC0298 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $219 $100 Implemented
NC0298 # 03 Y:2004 03 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $1,163 $800 Implemented
NC0298 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,603 $1,000 Not Implemented