Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 226 | Textile Finishing, Except Wool |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0499 # 02 Y:2013 | 02 | 2013 | OPERATE BOILERS ON HIGH FIRE SETTING | $17,607 | $1,000 | Implemented |
NC0225 # 04 Y:2001 | 04 | 2001 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $15,365 | $5,000 | Implemented |
NC0225 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,625 | $33,848 | Implemented |
NC0225 # 01 Y:2001 | 01 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,783 | $1,895 | Implemented |
NC0225 # 03 Y:2001 | 03 | 2001 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $27,745 | $33,990 | n/a |
NC0225 # 06 Y:2001 | 06 | 2001 | KEEP BOILER TUBES CLEAN | $3,649 | $13,000 | Implemented |
NC0225 # 05 Y:2001 | 05 | 2001 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $20,000 | $40,000 | n/a |
NC0225 # 08 Y:2001 | 08 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,105 | $100,000 | Implemented |
NC0225 # 07 Y:2001 | 07 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $8,655 | $3,500 | Implemented |
NC0204 # 04 Y:2000 | 04 | 2000 | AVOID REWINDING MOTORS MORE THAN TWICE | $1,634 | $1,282 | Not Implemented |
NC0204 # 06 Y:2000 | 06 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,422 | $1,100 | Implemented |
NC0204 # 05 Y:2000 | 05 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,960 | $730 | Implemented |
NC0204 # 11 Y:2000 | 11 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $375 | $500 | Implemented |
NC0204 # 08 Y:2000 | 08 | 2000 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $27,524 | $15,000 | Not Implemented |
NC0204 # 10 Y:2000 | 10 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,603 | $3,000 | Not Implemented |
NC0204 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,201 | $2,350 | Implemented |
NC0204 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,133 | $257 | Implemented |
NC0204 # 09 Y:2000 | 09 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $421 | $90 | Implemented |
NC0204 # 07 Y:2000 | 07 | 2000 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,074 | $1,000 | Implemented |
NC0204 # 03 Y:2000 | 03 | 2000 | DISCONNECT BALLASTS | $2,900 | $6,800 | Implemented |
NC0178 # 08 Y:1999 | 08 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,173 | $2,500 | Implemented |
NC0178 # 06 Y:1999 | 06 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $6,258 | $800 | Not Implemented |
NC0178 # 05 Y:1999 | 05 | 1999 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $10,689 | $16,800 | Not Implemented |
NC0178 # 03 Y:1999 | 03 | 1999 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $15,967 | $6,000 | Not Implemented |
NC0178 # 02 Y:1999 | 02 | 1999 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $14,400 | $5,600 | Implemented |