Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
647
matching recommendationsSIC | 2273 | Carpets And Rugs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0159 # 09 Y:1999 | 09 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $3,660 | $55 | Implemented |
WV0159 # 08 Y:1999 | 08 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $448 | $175 | Implemented |
WV0159 # 07 Y:1999 | 07 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,691 | $4,100 | Not Implemented |
WV0159 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,054 | $100 | Implemented |
WV0159 # 05 Y:1999 | 05 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,760 | $30 | Implemented |
WV0159 # 04 Y:1999 | 04 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,860 | $3,870 | Not Implemented |
WV0159 # 03 Y:1999 | 03 | 1999 | BURN A LESS EXPENSIVE GRADE OF FUEL | $60,045 | $26,400 | Not Implemented |
WV0159 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $18,085 | $24,240 | Not Implemented |
WV0159 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $566 | $512 | Implemented |
GT0645 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $20,559 | $10,000 | Implemented |
GT0645 # 02 Y:1998 | 02 | 1998 | USE MINIMUM SAFE OVEN VENTILATION | $2,720 | $0 | Not Implemented |
GT0645 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,810 | $7,000 | Implemented |
GT0645 # 04 Y:1998 | 04 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $34,362 | $22,000 | Implemented |
GT0645 # 05 Y:1998 | 05 | 1998 | PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING | $3,970 | $0 | Not Implemented |
GT0645 # 06 Y:1998 | 06 | 1998 | TREAT AND REUSE RINSE WATERS | $25,247 | $30,000 | Not Implemented |
GT0642 # 01 Y:1998 | 01 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $65,180 | $100,000 | Not Implemented |
GT0642 # 02 Y:1998 | 02 | 1998 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $8,990 | $0 | Not Implemented |
GT0642 # 03 Y:1998 | 03 | 1998 | COMBINE UTILITY METERS | $41,000 | $0 | Not Implemented |
GT0642 # 04 Y:1998 | 04 | 1998 | REPAIR OR REPLACE STEAM TRAPS | $23,695 | $13,000 | Not Implemented |
GT0642 # 05 Y:1998 | 05 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,530 | $12,500 | Not Implemented |
GT0642 # 06 Y:1998 | 06 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $26,700 | $40,500 | Not Implemented |
GT0642 # 07 Y:1998 | 07 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $35,596 | $52,700 | Not Implemented |
GT0642 # 08 Y:1998 | 08 | 1998 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $14,022 | $27,000 | Not Implemented |
GT0639 # 01 Y:1998 | 01 | 1998 | COMBINE UTILITY METERS | $10,670 | $0 | n/a |
GT0639 # 02 Y:1998 | 02 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,406 | $5,000 | n/a |