Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
910
matching recommendationsSIC | 229 | Miscellaneous Textile Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0377 # 05 Y:2000 | 05 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $17,748 | $24,000 | Not Implemented |
WI0377 # 06 Y:2000 | 06 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $10,494 | $20,500 | Not Implemented |
WI0377 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,592 | $8,205 | Implemented |
WI0377 # 08 Y:2000 | 08 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,629 | $23,136 | Implemented |
WI0377 # 09 Y:2000 | 09 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,343 | $7,200 | Implemented |
WI0377 # 10 Y:2000 | 10 | 2000 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,256 | $508 | Not Implemented |
WI0377 # 11 Y:2000 | 11 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $459 | $2,100 | Not Implemented |
WI0377 # 12 Y:2000 | 12 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $272 | $60 | Implemented |
WV0188 # 01 Y:2000 | 01 | 2000 | INSTALL SET-BACK TIMERS | $318 | $28 | Implemented |
WV0188 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $24 | $62 | Implemented |
WV0188 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $206 | $15 | Implemented |
WV0188 # 04 Y:2000 | 04 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $270 | $150 | Implemented |
WV0188 # 05 Y:2000 | 05 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,746 | $3,344 | Implemented |
WV0188 # 06 Y:2000 | 06 | 2000 | DISCONNECT BALLASTS | $5,102 | $1,527 | Implemented |
WV0188 # 07 Y:2000 | 07 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,937 | $0 | Not Implemented |
WV0188 # 08 Y:2000 | 08 | 2000 | USE OPTIMUM THICKNESS INSULATION | $73 | $176 | Not Implemented |
WV0188 # 09 Y:2000 | 09 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $708 | $693 | Implemented |
WV0188 # 10 Y:2000 | 10 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,187 | $0 | Implemented |
WV0188 # 11 Y:2000 | 11 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $44 | $0 | Not Implemented |
WV0188 # 12 Y:2000 | 12 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $9,344 | $336 | Not Implemented |
WV0188 # 13 Y:2000 | 13 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $20,000 | $6,000 | Not Implemented |
MA0457 # 01 Y:2000 | 01 | 2000 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $113,982 | $160,909 | Not Implemented |
MA0457 # 02 Y:2000 | 02 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $55,054 | $400,000 | Not Implemented |
MA0457 # 03 Y:2000 | 03 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,685 | $33,280 | Implemented |
MA0457 # 04 Y:2000 | 04 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,519 | $9,750 | Not Implemented |