IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
SIC 229 Miscellaneous Textile Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0158 # 05 Y:1999 05 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $12,762 $0 Not Implemented
NC0158 # 04 Y:1999 04 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $972 $907 Implemented
NC0158 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $3,937 $1,000 Not Implemented
NC0092 # 07 Y:1996 07 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $32,148 $1,904 Implemented
NC0092 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $314 $1,400 Implemented
NC0092 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,972 $708 Implemented
NC0092 # 03 Y:1996 03 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $27,124 $60,000 Implemented
NC0092 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $30,449 $20,428 Implemented
NC0092 # 05 Y:1996 05 1996 DISCONNECT BALLASTS $1,300 $1,430 Implemented
NC0092 # 06 Y:1996 06 1996 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $5,891 $50 Implemented
NC0092 # 08 Y:1996 08 1996 USE OPTIMUM THICKNESS INSULATION $164 $240 Implemented
NC0092 # 09 Y:1996 09 1996 USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING $100,360 $600,000 Not Implemented
NC0092 # 10 Y:1996 10 1996 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $26,400 $10,000 Implemented
NC0092 # 11 Y:1996 11 1996 USE LESS WASTEFUL PACKAGING $5,100 $0 Implemented
NC0055 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $658 $3,360 Implemented
NC0055 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,521 $1,200 Implemented
NC0055 # 02 Y:1995 02 1995 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $144,508 $638,000 Not Implemented
NC0055 # 03 Y:1995 03 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,431 $480 Implemented
NC0055 # 05 Y:1995 05 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,143 $28,000 Not Implemented
NC0055 # 06 Y:1995 06 1995 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $56,724 $55,000 Not Implemented
NC0055 # 07 Y:1995 07 1995 MINIMIZE WATER USAGE $8,114 $10,000 Not Implemented
NC0055 # 08 Y:1995 08 1995 MINIMIZE WATER USAGE $331,638 $1,750,000 Not Implemented
NC0054 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,438 $5,749 Implemented
NC0054 # 04 Y:1995 04 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,675 $475 Not Implemented
NC0054 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,362 $11,760 Not Implemented