Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

355

matching recommendations
Reset
SIC 2299 Textile Goods, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0712 # 08 Y:2001 08 2001 HEAT OIL TO PROPER TEMPERATURE FOR GOOD ATOMIZATION $154,042 $7,500 n/a
LE0107 # 01 Y:2001 01 2001 IMPROVE LUBRICATION PRACTICES $272 $200 Implemented
LE0107 # 02 Y:2001 02 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $639 $0 Implemented
LE0107 # 03 Y:2001 03 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $304 $0 Implemented
LE0107 # 04 Y:2001 04 2001 INSTALL SET-BACK TIMERS $7,324 $2,100 Not Implemented
LE0107 # 05 Y:2001 05 2001 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $853 $500 Not Implemented
LE0107 # 06 Y:2001 06 2001 USE OPTIMUM THICKNESS INSULATION $246 $350 Implemented
LE0107 # 07 Y:2001 07 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,622 $2,820 Not Implemented
ME0301 # 01 Y:2000 01 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $27,427 $27,427 Not Implemented
ME0301 # 02 Y:2000 02 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $12,375 $13,500 Not Implemented
ME0301 # 03 Y:2000 03 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $11,743 $35,073 Not Implemented
ME0301 # 04 Y:2000 04 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,346 $7,200 Not Implemented
ME0301 # 05 Y:2000 05 2000 RECOVER AND REUSE WASTE MATERIAL $7,500 $3,600 Not Implemented
ME0301 # 06 Y:2000 06 2000 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $5,000 $15,000 Not Implemented
WV0188 # 04 Y:2000 04 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $270 $150 Implemented
WV0188 # 13 Y:2000 13 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $20,000 $6,000 Not Implemented
WV0188 # 12 Y:2000 12 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $9,344 $336 Not Implemented
WV0188 # 11 Y:2000 11 2000 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $44 $0 Not Implemented
WV0188 # 10 Y:2000 10 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $3,187 $0 Implemented
WV0188 # 09 Y:2000 09 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $708 $693 Implemented
WV0188 # 08 Y:2000 08 2000 USE OPTIMUM THICKNESS INSULATION $73 $176 Not Implemented
WV0188 # 07 Y:2000 07 2000 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,937 $0 Not Implemented
WV0188 # 05 Y:2000 05 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $3,746 $3,344 Implemented
WV0188 # 03 Y:2000 03 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $206 $15 Implemented
WV0188 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $24 $62 Implemented