Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 2299 | Textile Goods, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0267 # 02 Y:2003 | 02 | 2003 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $6,222 | $9,225 | Not Implemented |
NC0267 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,018 | $9,911 | Not Implemented |
NC0267 # 04 Y:2003 | 04 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,686 | $700 | Implemented |
NC0267 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,004 | $12,000 | Implemented |
NC0267 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $100 | Implemented |
NC0267 # 07 Y:2003 | 07 | 2003 | RECOVER AND REUSE COOLING WATER | $64,159 | $0 | Not Implemented |
NC0267 # 01 Y:2003 | 01 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $869 | $0 | Not Implemented |
WI0447 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,071 | $2,000 | Not Implemented |
WI0447 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,938 | $2,600 | Implemented |
WI0447 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $381 | $740 | Not Implemented |
WI0447 # 02 Y:2003 | 02 | 2003 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $6,058 | $4,500 | Implemented |
WI0447 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $62,019 | $150,000 | Not Implemented |
TA0056 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $770 | $0 | Implemented |
TA0056 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $880 | $325 | Implemented |
TA0056 # 03 Y:2003 | 03 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,726 | $0 | Implemented |
TA0056 # 02 Y:2003 | 02 | 2003 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $13,500 | $1,075 | Not Implemented |
TA0056 # 01 Y:2003 | 01 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $190,000 | $141,875 | Not Implemented |
TA0056 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $1,128 | Implemented |
WV0258 # 13 Y:2003 | 13 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,945 | $250 | Implemented |
WV0258 # 12 Y:2003 | 12 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,489 | $200 | Implemented |
WV0258 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $7,852 | $2,734 | Implemented |
WV0258 # 10 Y:2003 | 10 | 2003 | USE OPTIMUM THICKNESS INSULATION | $3,010 | $518 | Not Implemented |
WV0258 # 09 Y:2003 | 09 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,163 | $220 | Implemented |
WV0258 # 08 Y:2003 | 08 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,129 | $525 | Implemented |
WV0258 # 07 Y:2003 | 07 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,432 | $1,000 | Implemented |