Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
239
matching recommendationsSIC | 23 | Apparel And Other Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0272 # 05 Y:2003 | 05 | 2003 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $351 | $900 | Not Implemented |
NC0264 # 02 Y:2003 | 02 | 2003 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $743 | $3,100 | Not Implemented |
NC0264 # 03 Y:2003 | 03 | 2003 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,182 | $3,115 | Not Implemented |
NC0264 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $454 | $630 | Implemented |
NC0264 # 05 Y:2003 | 05 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $463 | $800 | Not Implemented |
NC0264 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $152 | $627 | Implemented |
NC0264 # 07 Y:2003 | 07 | 2003 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,875 | $500 | Not Implemented |
NC0264 # 08 Y:2003 | 08 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $160 | $280 | Not Implemented |
NC0264 # 09 Y:2003 | 09 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $264 | $100 | Not Implemented |
NC0264 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,393 | $350 | Implemented |
NC0264 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $126 | $357 | Not Implemented |
NC0230 # 09 Y:2002 | 09 | 2002 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $4,254 | $3,500 | Implemented |
NC0230 # 01 Y:2002 | 01 | 2002 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $22,396 | $5,000 | Not Implemented |
NC0230 # 02 Y:2002 | 02 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $1,099 | $1,354 | Implemented |
NC0230 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $893 | $500 | Implemented |
NC0230 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,301 | $2,500 | Not Implemented |
NC0230 # 05 Y:2002 | 05 | 2002 | ADD AREA LIGHTING SWITCHES | $1,053 | $3,340 | Implemented |
NC0230 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $797 | $1,040 | Implemented |
NC0230 # 07 Y:2002 | 07 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $645 | $1,100 | Not Implemented |
NC0230 # 08 Y:2002 | 08 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $263 | $0 | Not Implemented |
GT0724 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,279 | $5,900 | Implemented |
GT0724 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,832 | $1,800 | Implemented |
GT0724 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,810 | $8,370 | n/a |
GT0724 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,554 | $0 | Not Implemented |
GT0724 # 05 Y:2001 | 05 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,956 | $7,500 | Implemented |