IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

138

matching recommendations
Reset
SIC 23 Apparel And Other Textile Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0450 # 06 Y:1994 06 1994 RECOVER WASTE HEAT FROM EQUIPMENT $419 $544 Implemented
OK0450 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $298 $655 Implemented
OK0372 # 01 Y:1992 01 1992 RECOVER WASTE HEAT FROM EQUIPMENT $588 $807 Not Implemented
OK0372 # 02 Y:1992 02 1992 INSTALL TIMERS AND/OR THERMOSTATS $3,782 $2,888 Implemented
OK0372 # 03 Y:1992 03 1992 KEEP LAMPS AND REFLECTORS CLEAN $4,890 $16,670 Implemented
OK0372 # 04 Y:1992 04 1992 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,558 $9,275 Not Implemented
OK0354 # 01 Y:1991 01 1991 KEEP LAMPS AND REFLECTORS CLEAN $7,243 $10,424 Implemented
OK0354 # 02 Y:1991 02 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $430 $0 Implemented
OK0354 # 03 Y:1991 03 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $50 $0 Implemented
OK0354 # 04 Y:1991 04 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $172 $0 Implemented
OK0354 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $6,989 $4,290 Implemented
OK0354 # 06 Y:1991 06 1991 INSTALL SET-BACK TIMERS $533 $202 Implemented
OK0354 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $85 $0 Implemented
OK0354 # 08 Y:1991 08 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $188 $0 Implemented
OK0346 # 01 Y:1991 01 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $857 $0 Implemented
OK0346 # 02 Y:1991 02 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,919 $0 Implemented
OK0346 # 03 Y:1991 03 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,122 $866 Implemented
OK0346 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,923 $1,500 Implemented
OK0346 # 05 Y:1991 05 1991 KEEP LAMPS AND REFLECTORS CLEAN $613 $0 Implemented
OK0340 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,387 $2,250 Not Implemented
OK0340 # 02 Y:1991 02 1991 RECOVER WASTE HEAT FROM EQUIPMENT $2,573 $232 Not Implemented
OK0340 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $207 $169 Not Implemented
OK0340 # 04 Y:1991 04 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $683 $0 Not Implemented
OK0271 # 01 Y:1988 01 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $307 $375 Implemented
OK0271 # 02 Y:1988 02 1988 RECOVER WASTE HEAT FROM EQUIPMENT $1,159 $1,070 Not Implemented