IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

99

matching recommendations
Reset
SIC 23 Apparel And Other Textile Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0506 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $905 $420 n/a
TN0506 # 01 Y:1993 01 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $1,385 $3,990 n/a
TN0506 # 08 Y:1993 08 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $92 $300 n/a
TN0446 # 04 Y:1991 04 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $488 $165 Implemented
TN0446 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $5,675 $2,700 Implemented
TN0446 # 02 Y:1991 02 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,089 $1,590 Implemented
TN0446 # 03 Y:1991 03 1991 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $507 $0 Implemented
TN0446 # 05 Y:1991 05 1991 KEEP LAMPS AND REFLECTORS CLEAN $1,068 $0 Implemented
TN0446 # 06 Y:1991 06 1991 INSULATE BARE EQUIPMENT $338 $859 Implemented
TN0414 # 01 Y:1990 01 1990 REPAIR AND ELIMINATE STEAM LEAKS $2,941 $500 Implemented
TN0414 # 02 Y:1990 02 1990 KEEP LAMPS AND REFLECTORS CLEAN $11,964 $0 Not Implemented
TN0414 # 03 Y:1990 03 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $2,891 $1,405 Implemented
TN0414 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,019 $3,000 Implemented
TN0414 # 05 Y:1990 05 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $810 $0 Implemented
TN0414 # 06 Y:1990 06 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $641 $200 Implemented
TN0414 # 07 Y:1990 07 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $862 $480 Implemented
TN0414 # 08 Y:1990 08 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $732 $0 Implemented
TN0396 # 01 Y:1990 01 1990 KEEP LAMPS AND REFLECTORS CLEAN $5,135 $19,742 Not Implemented
TN0396 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $770 $1,025 Implemented
TN0396 # 03 Y:1990 03 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,635 $0 Not Implemented
TN0396 # 04 Y:1990 04 1990 INSTALL SET-BACK TIMERS $462 $0 Implemented
TN0396 # 05 Y:1990 05 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $462 $360 Implemented
TN0396 # 06 Y:1990 06 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $290 $385 Not Implemented
TN0396 # 07 Y:1990 07 1990 IMPROVE LUBRICATION PRACTICES $290 $1,000 Not Implemented