Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,394
matching recommendationsSIC | 23 | Apparel And Other Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0327 # 01 Y:1990 | 01 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,470 | $1,250 | Implemented |
KU0327 # 02 Y:1990 | 02 | 1990 | INSULATE BARE EQUIPMENT | $5,349 | $12,000 | Implemented |
KU0327 # 03 Y:1990 | 03 | 1990 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,611 | $3,400 | Implemented |
KU0327 # 04 Y:1990 | 04 | 1990 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,567 | $987 | Not Implemented |
KU0327 # 05 Y:1990 | 05 | 1990 | INSULATE BARE EQUIPMENT | $2,509 | $3,000 | Implemented |
KU0327 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,487 | $2,600 | Implemented |
KU0327 # 07 Y:1990 | 07 | 1990 | INSTALL SET-BACK TIMERS | $1,982 | $2,300 | Not Implemented |
KU0327 # 08 Y:1990 | 08 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,480 | $2,400 | Implemented |
KU0327 # 09 Y:1990 | 09 | 1990 | ISOLATE HOT OR COLD EQUIPMENT | $1,337 | $355 | Implemented |
KU0327 # 10 Y:1990 | 10 | 1990 | DISCONNECT BALLASTS | $178 | $300 | Not Implemented |
KU0327 # 11 Y:1990 | 11 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $178 | $0 | Implemented |
TN0404 # 01 Y:1990 | 01 | 1990 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,398 | $4,800 | Not Implemented |
TN0404 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,555 | $390 | Implemented |
TN0404 # 03 Y:1990 | 03 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $2,724 | $11,289 | Not Implemented |
TN0404 # 04 Y:1990 | 04 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $760 | $0 | Implemented |
TN0404 # 05 Y:1990 | 05 | 1990 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,475 | $1,140 | Not Implemented |
TN0404 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $1,258 | $0 | Implemented |
TN0404 # 07 Y:1990 | 07 | 1990 | USE COMPRESSOR AIR FILTERS | $716 | $50 | Implemented |
TN0404 # 08 Y:1990 | 08 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $195 | $0 | Implemented |
TN0404 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $152 | $0 | Not Implemented |
TN0404 # 10 Y:1990 | 10 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $264 | Implemented |
OK0310 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,570 | $1,500 | Implemented |
OK0310 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $242 | Not Implemented |
OK0310 # 03 Y:1990 | 03 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,917 | $776 | Implemented |
OK0310 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $510 | $850 | Implemented |