Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 232 | Men's And Boys' Furnishings, Work Clothing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0404 # 01 Y:1990 | 01 | 1990 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,398 | $4,800 | Not Implemented |
TN0404 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,555 | $390 | Implemented |
TN0404 # 03 Y:1990 | 03 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $2,724 | $11,289 | Not Implemented |
TN0404 # 04 Y:1990 | 04 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $760 | $0 | Implemented |
TN0404 # 05 Y:1990 | 05 | 1990 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,475 | $1,140 | Not Implemented |
TN0404 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $1,258 | $0 | Implemented |
TN0404 # 07 Y:1990 | 07 | 1990 | USE COMPRESSOR AIR FILTERS | $716 | $50 | Implemented |
TN0404 # 08 Y:1990 | 08 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $195 | $0 | Implemented |
TN0404 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $152 | $0 | Not Implemented |
TN0404 # 10 Y:1990 | 10 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $264 | Implemented |
TN0396 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $5,135 | $19,742 | Not Implemented |
TN0396 # 02 Y:1990 | 02 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $770 | $1,025 | Implemented |
TN0396 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,635 | $0 | Not Implemented |
TN0396 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $462 | $0 | Implemented |
TN0396 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $462 | $360 | Implemented |
TN0396 # 06 Y:1990 | 06 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $290 | $385 | Not Implemented |
TN0396 # 07 Y:1990 | 07 | 1990 | IMPROVE LUBRICATION PRACTICES | $290 | $1,000 | Not Implemented |
TN0387 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,103 | $1,400 | Implemented |
TN0387 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,855 | $390 | Implemented |
TN0387 # 03 Y:1990 | 03 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $570 | $285 | Implemented |
TN0387 # 04 Y:1990 | 04 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $1,013 | $5,564 | Not Implemented |
TN0387 # 05 Y:1990 | 05 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $385 | $131 | Implemented |
TN0387 # 06 Y:1990 | 06 | 1990 | INSULATE BARE EQUIPMENT | $128 | $141 | Implemented |
TN0387 # 07 Y:1990 | 07 | 1990 | INSTALL SET-BACK TIMERS | $359 | $0 | Implemented |
TN0387 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $180 | Implemented |