Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

106

matching recommendations
Reset
SIC 2321 Men's and Boys' Shirts, Except Work Shirts
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0019 # 07 Y:1992 07 1992 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $338 $1,500 Not Implemented
UF0019 # 08 Y:1992 08 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,879 $6,854 Not Implemented
TN0434 # 01 Y:1991 01 1991 USE MINIMUM STEAM OPERATING PRESSURE $1,745 $2,550 Implemented
TN0434 # 02 Y:1991 02 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,163 $240 Implemented
TN0434 # 03 Y:1991 03 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,504 $3,650 Implemented
TN0434 # 04 Y:1991 04 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $117 $115 Implemented
TN0434 # 05 Y:1991 05 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $173 $410 Implemented
TN0434 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35 $128 Implemented
TN0434 # 07 Y:1991 07 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,785 $0 Implemented
MA0210 # 01 Y:1991 01 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $300 $136 Implemented
MA0210 # 02 Y:1991 02 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $191 $350 Implemented
MA0210 # 03 Y:1991 03 1991 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $651 $2,764 Implemented
MA0210 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $136 $47 Implemented
MA0210 # 05 Y:1991 05 1991 DIRECT WARMEST AIR TO COMBUSTION INTAKE $151 $405 Implemented
MA0210 # 06 Y:1991 06 1991 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $1,286 $2,375 Implemented
GT0429 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $788 $209 Implemented
GT0429 # 02 Y:1991 02 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $150 $1,130 Implemented
GT0429 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,175 $1,600 Implemented
GT0429 # 04 Y:1991 04 1991 REDUCE GLAZED AREAS IN BUILDINGS $1,806 $10,500 Implemented
GT0342 # 01 Y:1988 01 1988 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $60 $0 Implemented
GT0342 # 02 Y:1988 02 1988 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $30 $100 Implemented
GT0342 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,400 $13,460 Not Implemented
GT0342 # 04 Y:1988 04 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $86 $94 Not Implemented
AT0103 # 01 Y:1988 01 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,420 $1,000 Implemented
AT0103 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $291 $202 Implemented