Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

244

matching recommendations
Reset
SIC 2392 Housefurnishings, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0682 # 11 Y:2004 11 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,729 $130 Not Implemented
OK0682 # 13 Y:2004 13 2004 $1,600 $0 Implemented
OK0682 # 12 Y:2004 12 2004 $15,392 $10,000 Implemented
OK0682 # 01 Y:2004 01 2004 INSTALL SET-BACK TIMERS $1,572 $163 Implemented
OK0682 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $906 $6,187 Not Implemented
OK0682 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $96 $200 Not Implemented
OK0682 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $738 $682 Implemented
OK0682 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $892 $438 Implemented
OK0682 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $419 $3,000 Implemented
OK0682 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $132 $92 Not Implemented
OK0682 # 07 Y:2004 07 2004 UPGRADE CONTROLS ON COMPRESSORS $3,374 $15,000 Not Implemented
OK0682 # 08 Y:2004 08 2004 RECOVER WASTE HEAT FROM EQUIPMENT $4,455 $2,134 Not Implemented
OK0682 # 10 Y:2004 10 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $2,483 $1,200 Implemented
NC0230 # 02 Y:2002 02 2002 DEVELOP A REPAIR/REPLACE POLICY $1,099 $1,354 Implemented
NC0230 # 01 Y:2002 01 2002 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $22,396 $5,000 Not Implemented
NC0230 # 08 Y:2002 08 2002 USE RADIANT HEATER FOR SPOT HEATING $263 $0 Not Implemented
NC0230 # 04 Y:2002 04 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,301 $2,500 Not Implemented
NC0230 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $893 $500 Implemented
NC0230 # 07 Y:2002 07 2002 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $645 $1,100 Not Implemented
NC0230 # 06 Y:2002 06 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $797 $1,040 Implemented
NC0230 # 05 Y:2002 05 2002 ADD AREA LIGHTING SWITCHES $1,053 $3,340 Implemented
NC0230 # 09 Y:2002 09 2002 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $4,254 $3,500 Implemented
GT0724 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,832 $1,800 Implemented
GT0724 # 04 Y:2001 04 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,279 $5,900 Implemented
GT0724 # 02 Y:2001 02 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,554 $0 Not Implemented