Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0254 # 07 Y:1999 | 07 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $420 | $120 | Not Implemented |
AS0254 # 08 Y:1999 | 08 | 1999 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $51,100 | $13,200 | Implemented |
MS0135 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,827 | $1,406 | Implemented |
MS0135 # 02 Y:1999 | 02 | 1999 | USE PHOTOCELL CONTROLS | $590 | $334 | Implemented |
MS0135 # 03 Y:1999 | 03 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $381 | $355 | Implemented |
MS0135 # 04 Y:1999 | 04 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $30,074 | $1,180 | Not Implemented |
MS0135 # 05 Y:1999 | 05 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $983 | $70 | Implemented |
MS0135 # 06 Y:1999 | 06 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $314 | $25 | Implemented |
OD0136 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $862 | Implemented |
OD0136 # 02 Y:1999 | 02 | 1999 | DISCONNECT BALLASTS | $1,083 | $8,452 | Implemented |
OD0136 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $784 | $1,027 | Not Implemented |
OD0136 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $622 | $800 | Implemented |
OD0136 # 05 Y:1999 | 05 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,069 | $1,870 | Not Implemented |
OD0136 # 06 Y:1999 | 06 | 1999 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $7,187 | $2,200 | Not Implemented |
OD0137 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,022 | $5,528 | Implemented |
OD0137 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $839 | $400 | Implemented |
OD0137 # 03 Y:1999 | 03 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $90 | $100 | Not Implemented |
OD0137 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,840 | $1,000 | Implemented |
OD0137 # 05 Y:1999 | 05 | 1999 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $870 | $240 | Not Implemented |
OD0137 # 06 Y:1999 | 06 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $402 | $1,870 | Not Implemented |
NV0130 # 01 Y:1999 | 01 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,088 | $0 | Not Implemented |
NV0130 # 02 Y:1999 | 02 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,000 | $325 | Not Implemented |
NV0130 # 03 Y:1999 | 03 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,864 | $970 | Not Implemented |
UM0138 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,289 | $0 | Implemented |
UM0138 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $408 | $300 | Implemented |