Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0231 # 04 Y:1998 | 04 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $630 | $0 | Implemented |
ME0231 # 05 Y:1998 | 05 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $408 | $0 | Implemented |
ME0231 # 06 Y:1998 | 06 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $309 | $1,678 | Not Implemented |
ME0231 # 07 Y:1998 | 07 | 1998 | USE OPTIMUM THICKNESS INSULATION | $350 | $75 | Implemented |
ME0231 # 08 Y:1998 | 08 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $218 | $680 | Not Implemented |
ME0231 # 09 Y:1998 | 09 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $332 | $215 | Implemented |
ME0231 # 10 Y:1998 | 10 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,614 | $740 | Implemented |
ME0231 # 11 Y:1998 | 11 | 1998 | USE EVAPORATION TO CONCENTRATE MATERIAL | $2,275 | $5,748 | Not Implemented |
NV0096 # 01 Y:1998 | 01 | 1998 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,487 | $6,000 | Not Implemented |
NV0096 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $248 | $200 | Implemented |
NV0096 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $5,011 | $16,200 | Not Implemented |
NV0096 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,858 | $3,052 | Implemented |
NV0096 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $1,575 | $530 | Not Implemented |
NV0096 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $878 | $611 | Not Implemented |
NV0096 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $306 | Implemented |
NV0096 # 08 Y:1998 | 08 | 1998 | USE PHOTOCELL CONTROLS | $713 | $290 | Not Implemented |
NV0096 # 09 Y:1998 | 09 | 1998 | USE PHOTOCELL CONTROLS | $2,820 | $580 | Not Implemented |
NV0096 # 10 Y:1998 | 10 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $252 | $150 | Not Implemented |
NV0096 # 11 Y:1998 | 11 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $326 | $0 | Not Implemented |
NV0096 # 12 Y:1998 | 12 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $129,993 | $113,670 | Not Implemented |
NV0096 # 13 Y:1998 | 13 | 1998 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $1,500 | $0 | Not Implemented |
GT0631 # 01 Y:1997 | 01 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $57,241 | $66,640 | Not Implemented |
GT0631 # 02 Y:1997 | 02 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,202 | $0 | Not Implemented |
GT0631 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,860 | $300 | Implemented |
GT0631 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,350 | $11,600 | Not Implemented |