Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
307
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0425 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,944 | $21,313 | Implemented |
UF0425 # 11 Y:2009 | 11 | 2009 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $525 | $0 | Not Implemented |
UF0425 # 10 Y:2009 | 10 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $59,018 | $139,322 | Implemented |
UF0425 # 05 Y:2009 | 05 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $14,600 | $12,400 | Not Implemented |
UF0425 # 08 Y:2009 | 08 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,702 | $1,800 | Implemented |
UF0424 # 09 Y:2009 | 09 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,732 | $564 | Not Implemented |
UF0424 # 15 Y:2009 | 15 | 2009 | KEEP EQUIPMENT CLEAN | $1,885 | $816 | Not Implemented |
UF0424 # 14 Y:2009 | 14 | 2009 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $13,923 | $0 | Not Implemented |
UF0424 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $53,117 | $28,843 | Not Implemented |
UF0424 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $151 | $562 | Not Implemented |
UF0424 # 03 Y:2009 | 03 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $11,733 | $397 | Not Implemented |
UF0424 # 04 Y:2009 | 04 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,063 | $425 | Not Implemented |
UF0424 # 05 Y:2009 | 05 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $31,025 | $24,740 | Not Implemented |
UF0424 # 06 Y:2009 | 06 | 2009 | REDUCE HEAT GAIN BY WINDOW TINTING | $790 | $800 | Not Implemented |
UF0424 # 11 Y:2009 | 11 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,525 | $0 | Not Implemented |
UF0424 # 12 Y:2009 | 12 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $6,440 | $6,884 | Not Implemented |
UF0424 # 13 Y:2009 | 13 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $14,512 | $12,272 | Not Implemented |
UF0424 # 07 Y:2009 | 07 | 2009 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $512 | $2,500 | Not Implemented |
UF0424 # 08 Y:2009 | 08 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,080 | $512 | Not Implemented |
UF0424 # 10 Y:2009 | 10 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,752 | $300 | Not Implemented |
UF0416 # 03 Y:2008 | 03 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $53,629 | $49,236 | Not Implemented |
UF0416 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,189 | $227,490 | Not Implemented |
UF0416 # 05 Y:2008 | 05 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $5,057 | $0 | Not Implemented |
UF0416 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,217 | $0 | Implemented |
UF0416 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,708 | $1,477 | Implemented |