Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,223

matching recommendations
Reset
SIC 24 Lumber And Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0009 # 04 Y:1984 04 1984 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $327 $250 Not Implemented
CO0009 # 05 Y:1984 05 1984 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $107 $110 Implemented
CO0009 # 06 Y:1984 06 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,271 $5,000 Not Implemented
CO0009 # 07 Y:1984 07 1984 INSTALL TIMERS AND/OR THERMOSTATS $1,009 $500 Implemented
CO0009 # 08 Y:1984 08 1984 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $880 $455 Not Implemented
CO0009 # 09 Y:1984 09 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,099 $150 Implemented
KU0132 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,142 $6,807 Implemented
KU0132 # 02 Y:1984 02 1984 IMPROVE LUBRICATION PRACTICES $3,765 $800 Implemented
KU0132 # 03 Y:1984 03 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,978 $3,155 Implemented
KU0132 # 04 Y:1984 04 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,907 $1,150 Not Implemented
KU0132 # 05 Y:1984 05 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $903 $0 Implemented
KU0132 # 06 Y:1984 06 1984 INSTALL AUTOMATIC STACK DAMPER $840 $1,625 Not Implemented
KU0132 # 07 Y:1984 07 1984 SHUT OFF PILOTS IN STANDBY EQUIPMENT $238 $0 Not Implemented
KU0132 # 08 Y:1984 08 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,443 $85 Implemented
KU0132 # 09 Y:1984 09 1984 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,418 $1,110 Implemented
KU0132 # 10 Y:1984 10 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $171 $50 Not Implemented
KU0132 # 11 Y:1984 11 1984 REDUCE VENTILATION AIR $808 $0 Not Implemented
KU0132 # 12 Y:1984 12 1984 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $954 $0 Implemented
KU0132 # 13 Y:1984 13 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $662 $0 Implemented
KU0132 # 14 Y:1984 14 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $367 $800 Implemented
UD0133 # 01 Y:1984 01 1984 USE OPTIMUM THICKNESS INSULATION $5,281 $5,000 Not Implemented
UD0133 # 02 Y:1984 02 1984 USE OPTIMUM THICKNESS INSULATION $19,560 $40,500 Not Implemented
UD0133 # 03 Y:1984 03 1984 INSTALL SET-BACK TIMERS $1,754 $1,271 Implemented
UD0133 # 04 Y:1984 04 1984 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $3,629 $6,000 Implemented
UD0133 # 05 Y:1984 05 1984 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $1,721 $3,000 Not Implemented