Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

265

matching recommendations
Reset
SIC 24 Lumber And Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0462 # 06 Y:2012 06 2012 RECOVER WASTE HEAT FROM EQUIPMENT $7,686 $11,000 Implemented
NC0462 # 05 Y:2012 05 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $102 $200 Implemented
NC0462 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,190 $400 Implemented
NC0462 # 03 Y:2012 03 2012 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $8,910 $20,000 Not Implemented
NC0462 # 02 Y:2012 02 2012 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $107,890 $305,000 Not Implemented
NC0462 # 01 Y:2012 01 2012 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $21,080 $25,000 Not Implemented
NC0445 # 06 Y:2012 06 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,698 $7,891 Implemented
NC0445 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $336 $126 Implemented
NC0445 # 04 Y:2012 04 2012 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $17,271 $73,750 Not Implemented
NC0445 # 03 Y:2012 03 2012 RECOVER WASTE HEAT FROM EQUIPMENT $1,573 $7,197 Not Implemented
NC0445 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $575 $100 Implemented
NC0445 # 01 Y:2012 01 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,196 $0 Implemented
NC0427 # 12 Y:2011 12 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $126,880 $500,000 Not Implemented
NC0427 # 01 Y:2011 01 2011 BURN A LESS EXPENSIVE GRADE OF FUEL $155,882 $10,000 Implemented
NC0427 # 02 Y:2011 02 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $209,278 $1,200 Not Implemented
NC0427 # 03 Y:2011 03 2011 KEEP BOILER TUBES CLEAN $164,666 $20,000 Implemented
NC0427 # 04 Y:2011 04 2011 KEEP BOILER TUBES CLEAN $104,205 $18,000 Implemented
NC0427 # 05 Y:2011 05 2011 LOWER OPERATING PRESSURE OF CONDENSER (STEAM) $178,345 $50,000 Implemented
NC0427 # 06 Y:2011 06 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $10,000 $200 Implemented
NC0427 # 08 Y:2011 08 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,000 $600 Implemented
NC0427 # 07 Y:2011 07 2011 INSULATE FEEDWATER TANK $3,200 $1,200 Implemented
NC0427 # 11 Y:2011 11 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,050 Not Implemented
NC0427 # 09 Y:2011 09 2011 REPAIR AND ELIMINATE STEAM LEAKS $106,205 $1,200 Implemented
NC0427 # 10 Y:2011 10 2011 REPAIR OR REPLACE STEAM TRAPS $5,500 $150 Not Implemented
NC0416 # 04 Y:2010 04 2010 RECOVER WASTE HEAT FROM EQUIPMENT $11,462 $6,800 Not Implemented