Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0045 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,434 | $45,960 | Implemented |
TT0045 # 05 Y:2009 | 05 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $48,659 | $64,000 | Implemented |
TT0045 # 06 Y:2009 | 06 | 2009 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $182,907 | $0 | Not Implemented |
OR0551 # 01 Y:2009 | 01 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $77,191 | $50,820 | Implemented |
OR0551 # 02 Y:2009 | 02 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $28,529 | $42,146 | Implemented |
OR0551 # 03 Y:2009 | 03 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,500 | $0 | Not Implemented |
OR0551 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $28,320 | $48,980 | Implemented |
OR0551 # 05 Y:2009 | 05 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $83,890 | $100,800 | Implemented |
AM0564 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,930 | $21,500 | Implemented |
AM0564 # 02 Y:2009 | 02 | 2009 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,000 | $25,000 | Implemented |
AM0564 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,720 | $1,000 | Implemented |
AM0564 # 04 Y:2009 | 04 | 2009 | INSTALL SKYLIGHTS | $6,040 | $22,100 | Not Implemented |
AM0564 # 05 Y:2009 | 05 | 2009 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,070 | $0 | Not Implemented |
AM0564 # 06 Y:2009 | 06 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $715 | $0 | Implemented |
AM0564 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $690 | $305 | Implemented |
AM0564 # 08 Y:2009 | 08 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $450 | $0 | Implemented |
AM0564 # 09 Y:2009 | 09 | 2009 | USE SYNTHETIC LUBRICANT | $260 | $0 | Implemented |
OR0549 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $170,135 | $100,000 | Not Implemented |
OR0549 # 02 Y:2009 | 02 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $46,600 | $27,000 | Not Implemented |
OR0549 # 03 Y:2009 | 03 | 2009 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $28,000 | $700 | Not Implemented |
OR0549 # 04 Y:2009 | 04 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,682 | $0 | Implemented |
OR0549 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,800 | $3,500 | Implemented |
OR0548 # 01 Y:2009 | 01 | 2009 | KEEP SOLID FUELS / RAW MATERIALS DRY | $294,300 | $290,000 | Not Implemented |
OR0548 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $47,605 | $128,300 | Implemented |
OR0548 # 03 Y:2009 | 03 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $21,000 | $8,800 | Not Implemented |