IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
SIC 242 Sawmills And Planing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0166 # 09 Y:1999 09 1999 INSTALL EQUIPMENT TO MOVE PRODUCT $14,000 $15,500 Implemented
NC0166 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $756 $1,500 Implemented
NC0166 # 02 Y:1999 02 1999 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $5,877 $15,000 Not Implemented
NC0166 # 03 Y:1999 03 1999 USE PHOTOCELL CONTROLS $601 $150 Implemented
NC0166 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,328 $5,000 Not Implemented
NC0166 # 06 Y:1999 06 1999 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $645 $800 Not Implemented
NC0166 # 07 Y:1999 07 1999 BURN WOOD BY-PRODUCTS FOR HEAT $12,902 $62,200 Not Implemented
NC0166 # 05 Y:1999 05 1999 INSULATE FEEDWATER TANK $328 $340 Implemented
NC0166 # 08 Y:1999 08 1999 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $29,365 $82,000 Not Implemented
NC0166 # 10 Y:1999 10 1999 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $7,700 $1,000 Implemented
OD0136 # 06 Y:1999 06 1999 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $7,187 $2,200 Not Implemented
OD0136 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $232 $862 Implemented
OD0136 # 02 Y:1999 02 1999 DISCONNECT BALLASTS $1,083 $8,452 Implemented
OD0136 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $784 $1,027 Not Implemented
OD0136 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $622 $800 Implemented
OD0136 # 05 Y:1999 05 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,069 $1,870 Not Implemented
NC0126 # 03 Y:1997 03 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,564 $12,000 Not Implemented
NC0126 # 04 Y:1997 04 1997 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $6,974 $17,620 Not Implemented
NC0126 # 05 Y:1997 05 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,042 $5,200 Implemented
NC0126 # 07 Y:1997 07 1997 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $66,010 $220,000 Not Implemented
NC0126 # 08 Y:1997 08 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $962 $2,400 Not Implemented
NC0126 # 09 Y:1997 09 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $888 $1,314 Implemented
NC0126 # 10 Y:1997 10 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $35,268 $9,150 Not Implemented
NC0126 # 11 Y:1997 11 1997 ADD AREA LIGHTING SWITCHES $3,197 $2,420 Not Implemented
NC0126 # 12 Y:1997 12 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $143 $180 Implemented