Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
404
matching recommendationsSIC | 242 | Sawmills And Planing Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0568 # 02 Y:2011 | 02 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,800 | $1,390 | Not Implemented |
OR0568 # 01 Y:2011 | 01 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $13,790 | $2,100 | Not Implemented |
OR0563 # 04 Y:2010 | 04 | 2010 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,100,000 | $2,150,000 | Not Implemented |
OR0563 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $46,600 | $244,000 | Implemented |
OR0563 # 02 Y:2010 | 02 | 2010 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $219,003 | $250,000 | Implemented |
OR0563 # 01 Y:2010 | 01 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $35,913 | $17,860 | Not Implemented |
OR0547 # 10 Y:2009 | 10 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,270 | $15,676 | Implemented |
OR0547 # 09 Y:2009 | 09 | 2009 | COMBINE UTILITY METERS | $6,709 | $0 | Implemented |
OR0547 # 08 Y:2009 | 08 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,090 | $500 | Implemented |
OR0547 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,257 | $500 | Implemented |
OR0547 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $16,829 | $20,313 | Implemented |
OR0547 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,091 | $5,000 | Implemented |
OR0547 # 04 Y:2009 | 04 | 2009 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $705 | $0 | Implemented |
OR0547 # 03 Y:2009 | 03 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $939 | $1,042 | Implemented |
OR0547 # 02 Y:2009 | 02 | 2009 | KEEP BOILER TUBES CLEAN | $39,218 | $44,000 | Implemented |
OR0547 # 01 Y:2009 | 01 | 2009 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $90,740 | $81,950 | Not Implemented |
OR0502 # 06 Y:2006 | 06 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,280 | $72,900 | Implemented |
OR0502 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $12,600 | $48,600 | Implemented |
OR0502 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $18,300 | $27,500 | Implemented |
OR0502 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,300 | $6,300 | Implemented |
OR0502 # 02 Y:2006 | 02 | 2006 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $5,700 | $0 | Implemented |
OR0502 # 01 Y:2006 | 01 | 2006 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $5,052,000 | $0 | Not Implemented |
OR0486 # 12 Y:2005 | 12 | 2005 | INSULATE FEEDWATER TANK | $1,800 | $1,500 | Implemented |
OR0486 # 11 Y:2005 | 11 | 2005 | USE PHOTOCELL CONTROLS | $2,700 | $1,300 | Implemented |
OR0486 # 10 Y:2005 | 10 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $25,000 | $49,000 | Implemented |