IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

173

matching recommendations
Reset
SIC 242 Sawmills And Planing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0184 # 04 Y:2000 04 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,156 $220 Implemented
WV0184 # 05 Y:2000 05 2000 PAY BILLS ON TIME TO AVOID LATE FEES $40,958 $200 Implemented
WV0184 # 06 Y:2000 06 2000 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $4,706 $870 Not Implemented
WV0184 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,710 $11,000 Implemented
WV0184 # 08 Y:2000 08 2000 INSTALL EQUIPMENT TO MOVE PRODUCT $257,040 $105,000 Not Implemented
WV0112 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,723 $17,067 Not Implemented
WV0112 # 02 Y:1997 02 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,750 $485 Not Implemented
WV0112 # 03 Y:1997 03 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $2,378 $0 Not Implemented
WV0112 # 04 Y:1997 04 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,850 $35,000 Not Implemented
WV0112 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $958 $12 Not Implemented
WV0112 # 06 Y:1997 06 1997 RECOVER WASTE HEAT FROM EQUIPMENT $1,621 $485 Not Implemented
WV0112 # 07 Y:1997 07 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,218 $1,680 Not Implemented
WV0112 # 08 Y:1997 08 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $33,194 $100 Not Implemented
WV0112 # 09 Y:1997 09 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $39,600 $0 Not Implemented
WV0112 # 10 Y:1997 10 1997 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME $271,330 $4,000 Not Implemented
WV0091 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $61 $43 Implemented
WV0091 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $833 $3,726 Implemented
WV0091 # 03 Y:1996 03 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,048 $3,200 Implemented
WV0091 # 04 Y:1996 04 1996 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $10,600 $16,000 Not Implemented
WV0091 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $84 $210 Implemented
WV0091 # 06 Y:1996 06 1996 USE SYNTHETIC LUBRICANT $357 $350 Implemented
WV0091 # 07 Y:1996 07 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $264 $220 Not Implemented
WV0091 # 08 Y:1996 08 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $8,800 $0 Implemented