Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
SIC 242 Sawmills And Planing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0606 # 03 Y:2018 03 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,868 $20,154 Implemented
NC0606 # 10 Y:2018 10 2018 DEVELOP A REPAIR/REPLACE POLICY $27,412 $65,590 Implemented
NC0606 # 09 Y:2018 09 2018 REDESIGN PROCESS $31,091 $15,000 Implemented
NC0606 # 08 Y:2018 08 2018 REPAIR OR REPLACE STEAM TRAPS $11,945 $10,500 Implemented
NC0606 # 07 Y:2018 07 2018 INCREASE AMOUNT OF CONDENSATE RETURNED $205,770 $100,000 Not Implemented
NC0606 # 06 Y:2018 06 2018 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $21,044 $500 Implemented
NC0606 # 05 Y:2018 05 2018 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $48,482 $180,000 Implemented
NC0606 # 04 Y:2018 04 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,634 $200 Implemented
NC0606 # 02 Y:2018 02 2018 INSTALL OCCUPANCY SENSORS $369 $547 Implemented
NC0606 # 01 Y:2018 01 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $48,456 $119,341 Implemented
NC0445 # 01 Y:2012 01 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,196 $0 Implemented
NC0445 # 06 Y:2012 06 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,698 $7,891 Implemented
NC0445 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $336 $126 Implemented
NC0445 # 04 Y:2012 04 2012 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $17,271 $73,750 Not Implemented
NC0445 # 03 Y:2012 03 2012 RECOVER WASTE HEAT FROM EQUIPMENT $1,573 $7,197 Not Implemented
NC0445 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $575 $100 Implemented
NC0247 # 01 Y:2002 01 2002 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $44,473 $120,000 Implemented
NC0247 # 07 Y:2002 07 2002 DEVELOP A REPAIR/REPLACE POLICY $774 $863 Implemented
NC0247 # 06 Y:2002 06 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $427 $100 Implemented
NC0247 # 02 Y:2002 02 2002 INSTALL SKYLIGHTS $1,646 $540 Implemented
NC0247 # 03 Y:2002 03 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,600 $2,665 Implemented
NC0247 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $591 $1,597 Not Implemented
NC0247 # 09 Y:2002 09 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $860 $500 Implemented
NC0247 # 05 Y:2002 05 2002 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $10,011 $7,795 Not Implemented
NC0247 # 08 Y:2002 08 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,850 $1,004 Implemented