IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
SIC 243 Millwork, Plywood & Structural
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0273 # 09 Y:2019 09 2019 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,353 $80 Implemented
MZ0273 # 01 Y:2019 01 2019 SELL COMBUSTIBLE WASTE $16,000 $440 Not Implemented
MZ0273 # 08 Y:2019 08 2019 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,304 $390 Implemented
MZ0273 # 07 Y:2019 07 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,776 $3,070 Implemented
MZ0273 # 06 Y:2019 06 2019 INSTALL OCCUPANCY SENSORS $2,794 $630 Implemented
MZ0273 # 02 Y:2019 02 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,986 $1,880 Implemented
MZ0273 # 03 Y:2019 03 2019 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,770 $3,200 Implemented
MZ0273 # 04 Y:2019 04 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,520 $7,260 Not Implemented
MZ0273 # 05 Y:2019 05 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $3,687 $1,800 Implemented
KU0475 # 01 Y:1997 01 1997 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $4,260 $30,000 Not Implemented
KU0475 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $820 $230 Implemented
KU0475 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,250 $310 Implemented
KU0475 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $360 $480 Not Implemented
KU0475 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,290 $5,500 Not Implemented
KU0475 # 09 Y:1997 09 1997 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $37,520 $11,790 Implemented
KU0475 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $990 $4,090 Not Implemented
KU0475 # 06 Y:1997 06 1997 INSTALL OCCUPANCY SENSORS $490 $250 Not Implemented
KU0475 # 08 Y:1997 08 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $74,200 $1,500 Not Implemented
KU0453 # 01 Y:1995 01 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,320 $17,800 Not Implemented
KU0453 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $270 $350 Not Implemented
KU0453 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $939 $1,922 Not Implemented
KU0453 # 06 Y:1995 06 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $350 $79 Not Implemented
KU0453 # 07 Y:1995 07 1995 INSTALL TIMERS AND/OR THERMOSTATS $652 $600 Not Implemented
KU0453 # 08 Y:1995 08 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $349 $95 Not Implemented
KU0453 # 09 Y:1995 09 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $365 $340 Not Implemented