Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0366 # 07 Y:2005 | 07 | 2005 | MINIMIZE WATER USAGE | $4,699 | $20 | Implemented |
IA0366 # 06 Y:2005 | 06 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $25,383 | $83,500 | Not Implemented |
IA0366 # 05 Y:2005 | 05 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $182,520 | $28,170 | Not Implemented |
IA0366 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $281 | $539 | Not Implemented |
IA0366 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,172 | $19,200 | Not Implemented |
IA0366 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,055 | $307 | Not Implemented |
IA0366 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $623 | $72 | Not Implemented |
IA0363 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $20,328 | $0 | Implemented |
IA0363 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $971 | $2,171 | Not Implemented |
IA0363 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $859 | $1,617 | Not Implemented |
IA0363 # 07 Y:2005 | 07 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,742 | $95 | Not Implemented |
IA0363 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,962 | $1,023 | Implemented |
IA0363 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,383 | $15,627 | Implemented |
IA0363 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,682 | $12,835 | Not Implemented |
IA0363 # 01 Y:2005 | 01 | 2005 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,128 | $1,344 | Not Implemented |
IA0270 # 07 Y:2001 | 07 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,084 | $91 | Not Implemented |
IA0270 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $339 | $809 | Not Implemented |
IA0270 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $95 | $266 | Not Implemented |
IA0270 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,344 | $160 | Implemented |
IA0270 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $949 | $120 | Implemented |
IA0270 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $651 | $1,176 | Implemented |
IA0270 # 08 Y:2001 | 08 | 2001 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $27,169 | $14,000 | Not Implemented |
IA0270 # 10 Y:2001 | 10 | 2001 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $58,301 | $3,701 | Not Implemented |
IA0270 # 06 Y:2001 | 06 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $722 | $0 | Not Implemented |
IA0270 # 09 Y:2001 | 09 | 2001 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $114,660 | $46 | Not Implemented |