Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

437

matching recommendations
Reset
SIC 2434 Wood Kitchen Cabinets
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0576 # 04 Y:1996 04 1996 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $1,791 $0 Implemented
TN0576 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $867 $215 Not Implemented
TN0576 # 06 Y:1996 06 1996 INSTALL TIMERS AND/OR THERMOSTATS $809 $420 Implemented
AS0154 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,199 $2,108 Not Implemented
AS0154 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $388 $0 Implemented
AS0154 # 03 Y:1995 03 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,380 $2,600 Not Implemented
AS0154 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $554 $240 Implemented
AS0154 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $238 $200 Not Implemented
AS0154 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,282 $9,274 Implemented
AS0154 # 07 Y:1995 07 1995 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $358 $100 Not Implemented
AS0154 # 08 Y:1995 08 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,009 $700 Implemented
AS0154 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,111 $3,204 Not Implemented
AS0154 # 10 Y:1995 10 1995 INSTALL OCCUPANCY SENSORS $741 $1,350 Not Implemented
OR0223 # 01 Y:1994 01 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,968 $5,768 Implemented
OR0223 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,407 $4,000 Implemented
OR0223 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $558 $1,345 Implemented
OR0223 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,364 $4,800 Not Implemented
OR0223 # 05 Y:1994 05 1994 OPTIMIZE PLANT POWER FACTOR $695 $2,000 Implemented
OR0223 # 06 Y:1994 06 1994 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE $23,850 $106,600 Implemented
OR0223 # 07 Y:1994 07 1994 REDUCE SCRAP PRODUCTION $14,250 $6,500 Implemented
DS0011 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,409 $45,213 Not Implemented
DS0011 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $1,009 $400 Not Implemented
DS0011 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,818 $144 Implemented
DS0011 # 04 Y:1994 04 1994 USE RADIANT HEATER FOR SPOT HEATING $2,247 $7,200 Not Implemented
DS0011 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,319 $4,964 Implemented