Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

133

matching recommendations
Reset
SIC 244 Wood Containers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0210 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $710 $37 Implemented
WV0210 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,198 $54 Implemented
WV0210 # 05 Y:2001 05 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $5,488 $740 Implemented
WV0210 # 06 Y:2001 06 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,633 $900 Implemented
WV0210 # 07 Y:2001 07 2001 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS $3,772 $0 Implemented
WV0210 # 09 Y:2001 09 2001 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,808 $4,423 Implemented
WV0210 # 10 Y:2001 10 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $11,622 $0 Implemented
WV0210 # 11 Y:2001 11 2001 REUSE SCRAP GLASS AS FEED STOCK $180 $0 Implemented
OD0137 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,022 $5,528 Implemented
OD0137 # 02 Y:1999 02 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $839 $400 Implemented
OD0137 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,840 $1,000 Implemented
UM0138 # 01 Y:1999 01 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $1,289 $0 Implemented
UM0138 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $408 $300 Implemented
UM0138 # 05 Y:1999 05 1999 INSTALL EQUIPMENT TO MOVE PRODUCT $5,127 $0 Implemented
CO0432 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,030 $150 Implemented
AR0131 # 02 Y:1998 02 1998 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,297 $0 Implemented
AR0131 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $774 $90 Implemented
AR0131 # 07 Y:1998 07 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $23,082 $44,000 Implemented
AR0131 # 09 Y:1998 09 1998 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $71,804 $19,800 Implemented
UF0133 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,060 $1,000 Implemented
UF0133 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,052 $132 Implemented
UF0133 # 06 Y:1995 06 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,296 $2,705 Implemented
NC0063 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $776 $480 Implemented
NC0063 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $740 $95 Implemented
NC0063 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,719 $5,310 Implemented