Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

495

matching recommendations
Reset
SIC 245 Wood Buildings And Mobile Homes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0045 # 02 Y:2009 02 2009 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $24,604 $76,000 Not Implemented
TT0045 # 03 Y:2009 03 2009 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $13,478 $55,000 Not Implemented
TT0045 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,434 $45,960 Implemented
TT0045 # 05 Y:2009 05 2009 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $48,659 $64,000 Implemented
TT0045 # 06 Y:2009 06 2009 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $182,907 $0 Not Implemented
DL0040 # 01 Y:2009 01 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,947 $25,000 Not Implemented
DL0040 # 02 Y:2009 02 2009 RECOVER WASTE HEAT FROM EQUIPMENT $2,331 $2,350 Implemented
DL0040 # 03 Y:2009 03 2009 UPGRADE OBSOLETE EQUIPMENT $3,215 $0 Implemented
DL0040 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,110 $3,000 Implemented
DL0040 # 05 Y:2009 05 2009 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $12,823 $14,899 Not Implemented
DL0040 # 06 Y:2009 06 2009 INSTALL TIMERS AND/OR THERMOSTATS $4,313 $2,804 Not Implemented
DL0040 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,533 $38,218 Implemented
LE0258 # 01 Y:2007 01 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $13,092 $6,400 Not Implemented
LE0258 # 02 Y:2007 02 2007 USE RADIANT HEATER FOR SPOT HEATING $12,411 $18,750 Not Implemented
LE0258 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,871 $10,000 Not Implemented
LE0258 # 04 Y:2007 04 2007 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $6,874 $5,000 Not Implemented
LE0258 # 05 Y:2007 05 2007 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $767 $150 Not Implemented
LE0258 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,367 $40,684 Not Implemented
LE0258 # 07 Y:2007 07 2007 INSTALL OCCUPANCY SENSORS $387 $1,400 Not Implemented
AS0413 # 01 Y:2006 01 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $21,882 $1,000 Implemented
AS0413 # 02 Y:2006 02 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $18,423 $15,000 Implemented
AS0413 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,455 $15,000 Implemented
AM0460 # 01 Y:2004 01 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,110 $0 Implemented
AM0460 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,700 $80 Implemented
AM0460 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,600 $1,500 Implemented