Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,425
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0989 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $616 | $5,983 | Not Implemented |
UU0135 # 01 Y:2018 | 01 | 2018 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $10,541 | $800 | Not Implemented |
UU0135 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,170 | $993 | Implemented |
UU0135 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,077 | $1,970 | Not Implemented |
UU0135 # 04 Y:2018 | 04 | 2018 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,749 | $900 | Implemented |
WV0557 # 01 Y:2018 | 01 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $65,760 | $117,200 | Implemented |
WV0557 # 02 Y:2018 | 02 | 2018 | REPAIR AND ELIMINATE STEAM LEAKS | $43,281 | $33,600 | Implemented |
WV0557 # 03 Y:2018 | 03 | 2018 | ADD AREA LIGHTING SWITCHES | $22,313 | $25,000 | Not Implemented |
WV0557 # 04 Y:2018 | 04 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $13,930 | $2,320 | Implemented |
WV0557 # 05 Y:2018 | 05 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $14,479 | $27,450 | Implemented |
WV0557 # 06 Y:2018 | 06 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,808 | $0 | Not Implemented |
WV0557 # 07 Y:2018 | 07 | 2018 | INSULATE BARE EQUIPMENT | $3,480 | $16,000 | Not Implemented |
WV0557 # 08 Y:2018 | 08 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,390 | $1,950 | Not Implemented |
WV0557 # 09 Y:2018 | 09 | 2018 | MINIMIZE WATER USAGE | $2,486 | $5,600 | Not Implemented |
WV0557 # 10 Y:2018 | 10 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,424 | $90 | Not Implemented |
WV0557 # 11 Y:2018 | 11 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,022 | $1,365 | Not Implemented |
WV0557 # 12 Y:2018 | 12 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $508 | $2,480 | Implemented |
NL0004 # 01 Y:2017 | 01 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $93,000 | $125,000 | Implemented |
NL0004 # 02 Y:2017 | 02 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $65,107 | $300,000 | Implemented |
NL0004 # 03 Y:2017 | 03 | 2017 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $30,789 | $30,000 | Implemented |
NL0004 # 04 Y:2017 | 04 | 2017 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $6,396 | $1,100 | Implemented |
NL0004 # 05 Y:2017 | 05 | 2017 | COVER OPEN TANKS | $4,000 | $5,200 | Implemented |
NL0004 # 06 Y:2017 | 06 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $823 | $2,300 | Implemented |
AM0728 # 10 Y:2017 | 10 | 2017 | USE SYNTHETIC LUBRICANT | $386 | $0 | Implemented |
AM0728 # 09 Y:2017 | 09 | 2017 | PAY UTILITY BILLS ON TIME | $676 | $0 | Implemented |