Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0388 # 02 Y:1989 | 02 | 1989 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,300 | $10,000 | Not Implemented |
GT0388 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $278 | $230 | Implemented |
GT0388 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $626 | $0 | Implemented |
GT0388 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $190 | $410 | Implemented |
GT0388 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25 | $15 | Implemented |
GT0388 # 07 Y:1989 | 07 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $70 | $45 | Not Implemented |
GT0388 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,330 | $3,000 | Not Implemented |
OR0066 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,387 | $2,392 | Not Implemented |
OR0066 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,545 | $1,252 | Implemented |
OR0066 # 02 Y:1989 | 02 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,778 | $600 | Implemented |
OR0066 # 01 Y:1989 | 01 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,525 | $110 | Implemented |
OR0066 # 05 Y:1989 | 05 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $3,480 | $4,912 | Implemented |
OR0066 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,103 | $36,047 | Implemented |
OR0066 # 07 Y:1989 | 07 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $631 | $983 | Implemented |
OR0064 # 02 Y:1989 | 02 | 1989 | INSTALL SET-BACK TIMERS | $467 | $0 | Implemented |
OR0064 # 05 Y:1989 | 05 | 1989 | OPTIMIZE PLANT POWER FACTOR | $1,704 | $975 | Implemented |
OR0062 # 01 Y:1989 | 01 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,178 | $418 | Implemented |
OR0062 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,507 | $768 | Implemented |
OR0062 # 03 Y:1989 | 03 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $500 | $255 | Implemented |
OR0062 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,561 | $1,210 | Implemented |
OR0062 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $518 | $467 | Implemented |
OR0062 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $227 | $300 | Not Implemented |
OR0062 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $642 | $1,144 | Implemented |
OR0062 # 08 Y:1989 | 08 | 1989 | OPTIMIZE PLANT POWER FACTOR | $5,423 | $11,400 | Not Implemented |
OR0064 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $559 | $175 | Not Implemented |