IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
SIC 249 Miscellaneous Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0385 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,574 $14,352 Not Implemented
MS0385 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,570 $351 Not Implemented
MS0385 # 04 Y:2011 04 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $521 $670 Not Implemented
MS0385 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $192 $470 Not Implemented
MS0385 # 01 Y:2011 01 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,422 $5,076 Not Implemented
OR0575 # 01 Y:2011 01 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $1,800 $0 Not Implemented
OR0575 # 02 Y:2011 02 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $7,781 $500 Not Implemented
OR0575 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,748 $3,023 Implemented
OR0575 # 07 Y:2011 07 2011 INSTALL OCCUPANCY SENSORS $4,280 $2,630 Not Implemented
OR0575 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $3,389 $948 Implemented
OR0575 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $8,400 $7,692 Not Implemented
OR0575 # 06 Y:2011 06 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $3,994 $16,460 Not Implemented
OR0572 # 08 Y:2011 08 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,310 $1,170 Not Implemented
OR0572 # 07 Y:2011 07 2011 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $1,280 $500 Implemented
OR0572 # 06 Y:2011 06 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,030 $14,750 Not Implemented
OR0572 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,070 $4,559 Not Implemented
OR0572 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,350 $4,320 Implemented
OR0572 # 03 Y:2011 03 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $770 $2,280 Not Implemented
OR0572 # 02 Y:2011 02 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,220 $2,280 Not Implemented
OR0572 # 01 Y:2011 01 2011 UPGRADE CONTROLS ON COMPRESSORS $6,860 $3,642 Implemented
NC0427 # 01 Y:2011 01 2011 BURN A LESS EXPENSIVE GRADE OF FUEL $155,882 $10,000 Implemented
NC0427 # 06 Y:2011 06 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $10,000 $200 Implemented
NC0427 # 07 Y:2011 07 2011 INSULATE FEEDWATER TANK $3,200 $1,200 Implemented
NC0427 # 10 Y:2011 10 2011 REPAIR OR REPLACE STEAM TRAPS $5,500 $150 Not Implemented
NC0427 # 11 Y:2011 11 2011 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,050 Not Implemented