Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

410

matching recommendations
Reset
SIC 2493 Reconstituted Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0237 # 04 Y:2005 04 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $34,402 $1,400 Implemented
LL0237 # 05 Y:2005 05 2005 USE PHOTOCELL CONTROLS $22,793 $0 Not Implemented
LL0237 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,071 $0 Not Implemented
LL0237 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $1,195 $0 Not Implemented
LL0237 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,527 $1,930 Implemented
MA0565 # 01 Y:2004 01 2004 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $216,000 $125,000 Implemented
MA0565 # 02 Y:2004 02 2004 $57,540 $40,000 Implemented
MA0565 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,088 $8,000 Not Implemented
MA0565 # 04 Y:2004 04 2004 REPLACE BOILER $2,760 $750 Implemented
MA0565 # 05 Y:2004 05 2004 INSULATE BARE EQUIPMENT $2,705 $754 Implemented
MA0565 # 06 Y:2004 06 2004 INSULATE FEEDWATER TANK $873 $300 Implemented
MA0565 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $656 $548 Not Implemented
NC0257 # 01 Y:2003 01 2003 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $169,269 $200,000 Not Implemented
NC0257 # 02 Y:2003 02 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $24,665 $10,000 Not Implemented
NC0257 # 03 Y:2003 03 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $42,749 $55,000 Not Implemented
NC0257 # 04 Y:2003 04 2003 BURN A LESS EXPENSIVE GRADE OF FUEL $335,124 $425,000 n/a
NC0257 # 05 Y:2003 05 2003 DEVELOP A REPAIR/REPLACE POLICY $8,216 $8,241 Implemented
NC0257 # 06 Y:2003 06 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,771 $2,118 Implemented
NC0257 # 07 Y:2003 07 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,455 $500 Implemented
NC0257 # 08 Y:2003 08 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,407 $840 Implemented
NC0257 # 09 Y:2003 09 2003 USE PHOTOCELL CONTROLS $1,346 $1,540 Implemented
OR0425 # 01 Y:2003 01 2003 RECOVER WASTE HEAT FROM EQUIPMENT $1,195,313 $104,295 Not Implemented
OR0425 # 02 Y:2003 02 2003 $484,000 $420,000 Not Implemented
OR0425 # 03 Y:2003 03 2003 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $121,380 $120,000 n/a
OR0425 # 04 Y:2003 04 2003 $190,600 $553,000 Not Implemented