Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsSIC | 2493 | Reconstituted Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0716 # 06 Y:2001 | 06 | 2001 | FILTER AND REUSE HYDRAULIC OIL | $18,150 | $5,900 | n/a |
GT0716 # 05 Y:2001 | 05 | 2001 | FILTER AND REUSE HYDRAULIC OIL | $9,825 | $0 | n/a |
GT0716 # 04 Y:2001 | 04 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,000 | $2,000 | n/a |
GT0716 # 03 Y:2001 | 03 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $201 | $450 | n/a |
GT0716 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,800 | $0 | n/a |
GT0716 # 01 Y:2001 | 01 | 2001 | REDESIGN PROCESS | $807,905 | $500,000 | n/a |
GT0631 # 06 Y:1997 | 06 | 1997 | REDUCE VENTILATION AIR | $11,330 | $10,500 | Not Implemented |
GT0631 # 08 Y:1997 | 08 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $27,982 | $2,100 | Not Implemented |
GT0631 # 07 Y:1997 | 07 | 1997 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $3,460 | $1,000 | Not Implemented |
GT0631 # 05 Y:1997 | 05 | 1997 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $2,485 | $0 | Not Implemented |
GT0631 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,350 | $11,600 | Not Implemented |
GT0631 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,860 | $300 | Implemented |
GT0631 # 02 Y:1997 | 02 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,202 | $0 | Not Implemented |
GT0631 # 01 Y:1997 | 01 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $57,241 | $66,640 | Not Implemented |
GT0364 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $74 | $150 | Implemented |
GT0364 # 04 Y:1988 | 04 | 1988 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $19,102 | $28,000 | Not Implemented |
GT0364 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,433 | $0 | Implemented |
GT0364 # 02 Y:1988 | 02 | 1988 | IMPROVE LUBRICATION PRACTICES | $2,630 | $0 | Implemented |