Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 2493 | Reconstituted Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0455 # 07 Y:1999 | 07 | 1999 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $39,560 | $1,000 | n/a |
CO0455 # 06 Y:1999 | 06 | 1999 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $2,180 | $3,500 | n/a |
CO0455 # 05 Y:1999 | 05 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $39,330 | $0 | n/a |
CO0455 # 04 Y:1999 | 04 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $430 | $440 | n/a |
CO0455 # 03 Y:1999 | 03 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,640 | $0 | n/a |
CO0455 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,020 | $220 | n/a |
CO0455 # 01 Y:1999 | 01 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $41,240 | $10,000 | n/a |
AR0167 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,264 | $5,441 | Implemented |
AR0167 # 11 Y:1999 | 11 | 1999 | AUTOMATE FINISHING PROCESS | $80,703 | $51,700 | Not Implemented |
AR0167 # 10 Y:1999 | 10 | 1999 | USE OPTIMUM THICKNESS INSULATION | $86,793 | $85,710 | Not Implemented |
AR0167 # 09 Y:1999 | 09 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,707 | $1,791 | Implemented |
AR0167 # 08 Y:1999 | 08 | 1999 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $2,390,400 | $4,500,000 | Not Implemented |
AR0167 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,681 | $8,274 | Not Implemented |
AR0167 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,567 | $200 | Implemented |
AR0167 # 05 Y:1999 | 05 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,523 | $0 | Implemented |
AR0167 # 04 Y:1999 | 04 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $7,742 | $205 | Implemented |
AR0167 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,657 | $250 | Implemented |
AR0167 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $5,846 | $2,240 | Implemented |
OR0349 # 01 Y:1999 | 01 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $40,560 | $64,125 | Implemented |
OR0349 # 02 Y:1999 | 02 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $36,220 | $98,500 | Not Implemented |
OR0349 # 03 Y:1999 | 03 | 1999 | UPGRADE CONVEYORS | $18,725 | $46,000 | Not Implemented |
OR0349 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,088 | $10,000 | Implemented |
OR0349 # 05 Y:1999 | 05 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,171 | $0 | Not Implemented |
OR0349 # 06 Y:1999 | 06 | 1999 | UPGRADE CONTROLS ON COMPRESSORS | $24,695 | $2,840 | Implemented |
OR0349 # 07 Y:1999 | 07 | 1999 | INCREASE USE OF AUTOMATION | $179,000 | $42,000 | Not Implemented |