Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
132
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0658 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,160 | $1,400 | Not Implemented |
TN0658 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,780 | $2,630 | Implemented |
TN0658 # 01 Y:1999 | 01 | 1999 | BURN WOOD BY-PRODUCTS FOR HEAT | $194,600 | $52,000 | Not Implemented |
TN0658 # 02 Y:1999 | 02 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $120,000 | $2,400 | Not Implemented |
TN0658 # 07 Y:1999 | 07 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,360 | $1,330 | Not Implemented |
TN0658 # 08 Y:1999 | 08 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $4,000 | Implemented |
TN0658 # 09 Y:1999 | 09 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $700 | $810 | Not Implemented |
TN0658 # 10 Y:1999 | 10 | 1999 | USE SYNTHETIC LUBRICANT | $650 | $0 | Not Implemented |
TN0621 # 01 Y:1997 | 01 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $24,470 | $4,300 | Not Implemented |
TN0621 # 02 Y:1997 | 02 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $17,500 | $17,900 | Implemented |
TN0621 # 03 Y:1997 | 03 | 1997 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $14,220 | $27,690 | Not Implemented |
TN0621 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,400 | $0 | Not Implemented |
TN0621 # 04 Y:1997 | 04 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $8,175 | $9,600 | Not Implemented |
TN0621 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $655 | $0 | Not Implemented |
TN0621 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,980 | $17,100 | Not Implemented |
TN0621 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,710 | $17,000 | Not Implemented |
TN0621 # 08 Y:1997 | 08 | 1997 | MAINTAIN MACHINES TO REDUCE LEAKS | $1,980 | $2,780 | Implemented |
TN0553 # 04 Y:1995 | 04 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,284 | $20,800 | Not Implemented |
TN0553 # 02 Y:1995 | 02 | 1995 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,313 | $1,320 | Implemented |
TN0553 # 01 Y:1995 | 01 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $810 | $0 | Implemented |
TN0553 # 03 Y:1995 | 03 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $853 | $0 | Implemented |
TN0530 # 10 Y:1994 | 10 | 1994 | MAKE A NEW BY-PRODUCT | $100,000 | $988,447 | Implemented |
TN0530 # 11 Y:1994 | 11 | 1994 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $341,760 | $52,450 | Not Implemented |
TN0530 # 12 Y:1994 | 12 | 1994 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $13,320 | $2,664 | Not Implemented |
TN0530 # 13 Y:1994 | 13 | 1994 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,705 | $8,521 | Not Implemented |