Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,525

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0073 # 08 Y:2004 08 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,302 $10,000 Not Implemented
LM0073 # 09 Y:2004 09 2004 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $27,520 $4,000 Implemented
LM0073 # 10 Y:2004 10 2004 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $207,176 $0 Not Implemented
LM0073 # 11 Y:2004 11 2004 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $10,400 $1,562 Implemented
LM0073 # 12 Y:2004 12 2004 DEVELOP STANDARD OPERATING PROCEDURES $33,857 $9,860 Not Implemented
TA0072 # 01 Y:2004 01 2004 USE RADIANT HEATER FOR SPOT HEATING $25,095 $4,666 Not Implemented
TA0072 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $13,600 $0 Implemented
TA0072 # 03 Y:2004 03 2004 AIR CONDITION ONLY SPACE NECESSARY $7,680 $150 Not Implemented
TA0072 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,360 $190 Implemented
TA0072 # 05 Y:2004 05 2004 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $775 $0 Implemented
TA0072 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $210 $320 Implemented
WI0463 # 01 Y:2004 01 2004 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $75,927 $18,500 Not Implemented
WI0463 # 02 Y:2004 02 2004 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $17,690 $17,690 Not Implemented
WI0463 # 03 Y:2004 03 2004 RECOVER WASTE HEAT FROM EQUIPMENT $15,360 $2,000 Not Implemented
WI0463 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,859 $29,148 Not Implemented
WI0463 # 05 Y:2004 05 2004 UPGRADE CONTROLS ON COMPRESSORS $11,920 $12,595 Not Implemented
WI0463 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,605 $840 Not Implemented
WI0463 # 07 Y:2004 07 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,530 $15,200 Not Implemented
MS0245 # 01 Y:2004 01 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $82,017 $6,780 Not Implemented
MS0245 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,496 $15,583 Not Implemented
MS0245 # 03 Y:2004 03 2004 REPLACE BOILER $6,523 $4,642 Not Implemented
MS0245 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $3,354 $1,036 Not Implemented
MS0245 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,071 $156 Implemented
MS0245 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,263 $1,542 Not Implemented
MS0245 # 07 Y:2004 07 2004 INSTALL TIMERS AND/OR THERMOSTATS $216 $355 Not Implemented