Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,525

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0088 # 08 Y:1997 08 1997 INSTALL AUTOMATIC PACKING EQUIPMENT $60,750 $7,646 Implemented
UL0180 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $135 $3,650 Not Implemented
UL0180 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $289 $2,813 Implemented
UL0180 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $526 $87 Not Implemented
UL0180 # 04 Y:1997 04 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $8,150 $0 Implemented
UL0180 # 05 Y:1997 05 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,000 $17,500 Implemented
UL0180 # 06 Y:1997 06 1997 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $19,400 $3,600 Implemented
MS0086 # 01 Y:1997 01 1997 USE SYNTHETIC LUBRICANT $1,444 $132 Implemented
MS0086 # 02 Y:1997 02 1997 RECOVER WASTE HEAT FROM EQUIPMENT $1,963 $5,372 Not Implemented
MS0086 # 03 Y:1997 03 1997 OPTIMIZE PLANT POWER FACTOR $1,998 $1,500 Implemented
MS0086 # 04 Y:1997 04 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $463 $880 Not Implemented
MS0086 # 05 Y:1997 05 1997 USE PHOTOCELL CONTROLS $3,037 $722 Not Implemented
MS0086 # 06 Y:1997 06 1997 RECOVER WASTE HEAT FROM EQUIPMENT $201 $287 Implemented
MS0086 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $16,230 $7,925 Implemented
MS0086 # 08 Y:1997 08 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $20,100 $0 Not Implemented
MS0086 # 09 Y:1997 09 1997 REUSE / RECYCLE/ SELL PAPER PRODUCTS $2,556 $0 Implemented
MS0086 # 10 Y:1997 10 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $46,900 $0 Not Implemented
MS0086 # 11 Y:1997 11 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $18,007 $25,000 Not Implemented
MS0086 # 12 Y:1997 12 1997 COMBINE UTILITY METERS $1,499 $1,920 Implemented
MA0389 # 01 Y:1997 01 1997 PAY BILLS ON TIME TO AVOID LATE FEES $2,061 $0 Not Implemented
MA0389 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,610 $2,100 Not Implemented
MA0389 # 03 Y:1997 03 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $592 $860 Implemented
MA0389 # 04 Y:1997 04 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $565 $0 Implemented
MA0389 # 05 Y:1997 05 1997 CHECK FOR ACCURACY OF UTILITY / POWER METERS $538 $60 Implemented
MA0389 # 06 Y:1997 06 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $298 $75 Implemented