Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
282
matching recommendationsSIC | 252 | Office Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0104 # 03 Y:1995 | 03 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,691 | $700 | Implemented |
IA0104 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $134 | $343 | Implemented |
UD0429 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $585 | $1,250 | Implemented |
UD0429 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $249 | $44 | Implemented |
OK0439 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,701 | $12,214 | Implemented |
OK0439 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $187 | $200 | Implemented |
OK0439 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $766 | $0 | Implemented |
IA0077 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,776 | $13,208 | Implemented |
IA0077 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $609 | $100 | Implemented |
MO0107 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,689 | $16,563 | Implemented |
MO0107 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,418 | $641 | Implemented |
MO0107 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $728 | Implemented |
MO0107 # 09 Y:1994 | 09 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,301 | $775 | Implemented |
MO0107 # 10 Y:1994 | 10 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,211 | $3,010 | Implemented |
MO0107 # 12 Y:1994 | 12 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,162 | $1,547 | Implemented |
MO0107 # 13 Y:1994 | 13 | 1994 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $460 | $40 | Implemented |
GT0505 # 01 Y:1993 | 01 | 1993 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,090 | $1,600 | Implemented |
GT0505 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,370 | $6,400 | Implemented |
GT0505 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,250 | $830 | Implemented |
GT0505 # 07 Y:1993 | 07 | 1993 | USE RADIANT HEATER FOR SPOT HEATING | $11,700 | $80,000 | Implemented |
NC0010 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,824 | $11,100 | Implemented |
NC0010 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $844 | $1,850 | Implemented |
NC0010 # 06 Y:1993 | 06 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $278 | $0 | Implemented |
NC0008 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,091 | $13,201 | Implemented |
NC0008 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,736 | $13,007 | Implemented |