Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
361
matching recommendationsSIC | 2521 | Wood Office Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0591 # 06 Y:2017 | 06 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,119 | $20,000 | Not Implemented |
SU0406 # 07 Y:2016 | 07 | 2016 | REPLACE BOILER | $8,344 | $37,133 | Implemented |
SU0406 # 06 Y:2016 | 06 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $226 | $287 | Implemented |
SU0406 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $126 | $145 | Implemented |
SU0406 # 04 Y:2016 | 04 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $644 | $337 | Implemented |
SU0406 # 03 Y:2016 | 03 | 2016 | ELIMINATE/REDUCE AN OPERATION | $3,795 | $1,535 | Not Implemented |
SU0406 # 02 Y:2016 | 02 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,714 | $0 | Implemented |
SU0406 # 01 Y:2016 | 01 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,885 | $0 | Implemented |
WM0073 # 17 Y:2015 | 17 | 2015 | INSTALL OCCUPANCY SENSORS | $133 | $268 | Not Implemented |
WM0073 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,390 | $4,800 | Implemented |
WM0073 # 02 Y:2015 | 02 | 2015 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $11,105 | $9,052 | Not Implemented |
WM0073 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,465 | $25,360 | Not Implemented |
WM0073 # 04 Y:2015 | 04 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,673 | $334 | Implemented |
WM0073 # 06 Y:2015 | 06 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,049 | $132 | Implemented |
WM0073 # 16 Y:2015 | 16 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $125 | Implemented |
WM0073 # 15 Y:2015 | 15 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $471 | $130 | Not Implemented |
WM0073 # 14 Y:2015 | 14 | 2015 | INSTALL OCCUPANCY SENSORS | $520 | $100 | Not Implemented |
WM0073 # 13 Y:2015 | 13 | 2015 | USE SYNTHETIC LUBRICANT | $654 | $1,155 | Implemented |
WM0073 # 12 Y:2015 | 12 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,070 | $391 | Implemented |
WM0073 # 11 Y:2015 | 11 | 2015 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $15,300 | $5,570 | Not Implemented |
WM0073 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $134 | $268 | Not Implemented |
WM0073 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $288 | $100 | Implemented |
WM0073 # 08 Y:2015 | 08 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $423 | $380 | Implemented |
WM0073 # 07 Y:2015 | 07 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $974 | $527 | Not Implemented |
WM0073 # 05 Y:2015 | 05 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,166 | $4,202 | Not Implemented |