Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
385
matching recommendationsSIC | 253 | Public Building & Related Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0030 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $2,438 | $1,225 | Not Implemented |
IC0030 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,602 | $25,370 | Implemented |
IC0030 # 05 Y:2002 | 05 | 2002 | MODIFY WORKLOAD | $132,950 | $36,600 | Implemented |
IC0030 # 06 Y:2002 | 06 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $9,840 | $250 | Not Implemented |
WV0232 # 15 Y:2002 | 15 | 2002 | $8,700 | $500 | Not Implemented | |
WV0232 # 14 Y:2002 | 14 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $4,680 | $100 | Implemented |
WV0232 # 13 Y:2002 | 13 | 2002 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $16,400 | $60 | Implemented |
WV0232 # 12 Y:2002 | 12 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,400 | $1,930 | Not Implemented |
WV0232 # 11 Y:2002 | 11 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,899 | $1,270 | Not Implemented |
WV0232 # 10 Y:2002 | 10 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,421 | $0 | Implemented |
WV0232 # 09 Y:2002 | 09 | 2002 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,788 | $0 | Implemented |
WV0232 # 08 Y:2002 | 08 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,088 | $2,680 | Not Implemented |
WV0232 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $907 | $480 | Implemented |
WV0232 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $689 | $20 | Implemented |
WV0232 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $706 | $148 | Not Implemented |
WV0232 # 04 Y:2002 | 04 | 2002 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,818 | $300 | Implemented |
WV0232 # 03 Y:2002 | 03 | 2002 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $2,127 | $1,155 | Implemented |
WV0232 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,821 | $1,000 | Not Implemented |
WV0232 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $884 | $150 | Implemented |
SD0285 # 01 Y:2002 | 01 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $27,865 | $25,000 | Not Implemented |
SD0285 # 02 Y:2002 | 02 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,921 | $0 | Implemented |
SD0285 # 03 Y:2002 | 03 | 2002 | INSTALL SKYLIGHTS | $58,765 | $32,000 | Not Implemented |
SD0285 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,082 | $1,720 | Implemented |
SD0285 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,764 | $1,200 | Implemented |
SD0285 # 06 Y:2002 | 06 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $26,143 | $7,500 | Not Implemented |