Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

330

matching recommendations
Reset
SIC 2541 Wood Partitions And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CI0040 # 07 Y:2024 07 2024 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES $2,874 $7,990 n/a
CI0040 # 03 Y:2024 03 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $21,951 $31,000 n/a
CI0040 # 01 Y:2024 01 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $57,161 $288,868 n/a
CI0040 # 02 Y:2024 02 2024 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $34,278 $75,000 n/a
CI0040 # 05 Y:2024 05 2024 USE PHOTOCELL CONTROLS $5,246 $7,920 n/a
CI0040 # 04 Y:2024 04 2024 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION $7,997 $19,000 n/a
CI0040 # 06 Y:2024 06 2024 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,911 $6,699 n/a
UD1088 # 04 Y:2024 04 2024 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,430 $48,200 Not Implemented
UD1088 # 03 Y:2024 03 2024 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,590 $400 Not Implemented
UD1088 # 02 Y:2024 02 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,698 $6,900 Not Implemented
UD1088 # 06 Y:2024 06 2024 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $392 $1,225 Not Implemented
UD1088 # 05 Y:2024 05 2024 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,017 $0 Implemented
UD1088 # 01 Y:2024 01 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,165 $953 Implemented
MI0444 # 09 Y:2024 09 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $717 $2,430 Not Implemented
MI0444 # 04 Y:2024 04 2024 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $5,488 $965 Not Implemented
MI0444 # 01 Y:2024 01 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,690 $26,240 Not Implemented
MI0444 # 02 Y:2024 02 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,226 $1,016 Implemented
MI0444 # 08 Y:2024 08 2024 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $729 $34 Not Implemented
MI0444 # 03 Y:2024 03 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,757 $1,980 Implemented
MI0444 # 06 Y:2024 06 2024 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,309 $5,731 Not Implemented
MI0444 # 05 Y:2024 05 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,005 $9,012 Not Implemented
MI0444 # 07 Y:2024 07 2024 MINIMIZE WATER USAGE $1,521 $800 Implemented
MI0444 # 10 Y:2024 10 2024 INSTALL OCCUPANCY SENSORS $485 $903 Not Implemented
AM0911 # 06 Y:2024 06 2024 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $580 $0 n/a
AM0911 # 05 Y:2024 05 2024 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $795 $1,140 n/a